KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Apr-2007 | S | UFGS 03 30 00.00 40 Cast-in-Place Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 03 30 53.00 40 Miscellaneous Cast-in-Place Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 03 31 29 Marine Concrete with Service Life Modeling | Apr-2007 | R | Deleted superfluous note under Submittal Article, SD-07. | |
Apr-2007 | S | UFGS 03 41 33.00 40 Precast Structural Pretensioned Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 03 45 00.00 40 Precast Architectural Concrete | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 03 50 00.00 40 Cast Decks and Underlayments | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 05 14 00.13 Welding Structural Aluminum Framing | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 05 70 00.00 40 Decorative Metals | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 06 18 00 Glued-Laminated Construction | Apr-2007 | R | Titled changed from GLUE-LAMINATED STRUCTURAL UNITS; Reference Update | |
Apr-2007 | S | UFGS 07 40 00.00 40 Roofing and Siding Panels | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 08 13 73.00 40 Sliding Metal Doors | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 08 44 00.00 40 Curtain Wall and Glazed Assemblies | Apr-2007 | R | Section References (SRF) update | |
Apr-2007 | S | UFGS 08 51 13.00 40 Aluminum Windows | Apr-2007 | R | Section References (SRF) update | |
Apr-2007 | S | UFGS 09 30 16.00 40 Quarry Tiling | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 09 67 00.00 40 Fluid-Applied Flooring | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 10 51 00.00 40 Lockers | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 12 30 00.00 40 Casework | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 13 50 00.00 40 Special Instrumentation | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 21 13 00.00 40 Fire-Suppression Sprinkler Systems | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 21 13 26.00 40 Deluge Fire-Suppression Sprinkler Systems | Apr-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 22 00 00 Plumbing, General Purpose | Apr-2007 | R | Added chlorine filters to water supply to Air Force, NASA sinks, lavatories and tubs/showers: Corrected errors in installation heights of urinals and other fixtures. | |
Apr-2007 | S | UFGS 22 15 09 General Service Compressed-Air Systems Cleaning Procedures | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 22 15 13.16 40 High-Pressure Compressed-Air Piping and Valves, Stainless | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 00 00.00 40 Heating, Ventilating, and Air Conditioning | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 05 00.00 40 Common Work Results for HVAC | Apr-2007 | R | Reference Update | |
Apr-2007 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Apr-2007 | R | Minor change to paragraph Vapor Barrier/Weatherproofing Jacket | |
Apr-2007 | N | UFGS 23 08 00.00 20 Commissioning of Mechanical[ and Plumbing] Systems | Apr-2007 | R | Paragraph 1.8.4.2 Certified TAB Reports - list item d: (5) & (6): Reduced number of reporting sites required for medium size duct systems | |
Apr-2007 | N | UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC | Apr-2007 | R | Revised definitions, added guidance for BACnet Testing Labs (BTL) certification | |
Apr-2007 | S | UFGS 23 09 33.00 40 Electric and Electronic Control System for HVAC | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 11 23.00 40 Facility Natural-Gas Piping | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 23 16.00 40 Refrigerant Piping Specialties | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 41 13.00 40 Panel Filters | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 52 00.00 40 Heating Boilers | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 74 33.00 40 Small HVAC Units, Cooling-Only, Recirculating, Split and Unitary for Window and Floor Mounting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 81 43.00 40 Air-Source Unitary Heat Pumps | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 82 19.00 40 Fan Coil Units | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 23 82 23.00 40 Unit Ventilators | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 05 13.00 10 Medium-Voltage Cables | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 05 73.00 40 Overcurrent Protective Devices | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 12 00.00 40 Medium-Voltage Transformers | Apr-2007 | R | Reference Update | |
Apr-2007 | N | UFGS 26 32 13.00 20 Single Operation Generator Sets | Apr-2007 | R | Section note revised to add Capital Improvements requirements | |
Apr-2007 | S | UFGS 26 51 13.08 40 Incandescent Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 51 13.09 40 Fluorescent Luminaries | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 54 00.00 40 Classified, Special Purpose, Exterior Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 56 19.00 40 Roadway Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 26 56 36.00 40 Flood Lighting | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 28 05 26.00 40 Grounding and Bonding for Electrical Systems | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 28 33 00.00 40 Fuel-Gas Detection and Alarm | Apr-2007 | R | Reference Update | |
Apr-2007 | A | UFGS 32 12 15 Hot-Mix Asphalt (HMA) for Airfields | Apr-2007 | R | VMA and joints | |
Apr-2007 | S | UFGS 33 32 13.13 40 Packaged Sewage Lift Stations, Wet Well Type | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 33 40 00.00 40 Storm Drainage Utilities | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 33 75 00.00 40 Switchgear and Protection Devices | Apr-2007 | R | Section References (SRF) update | |
Apr-2007 | S | UFGS 40 18 00.00 40 Vacuum Systems Process Piping | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 40 95 33.23 40 Fiber Optic Process Control Networks | Apr-2007 | R | Reference Update | |
Apr-2007 | S | UFGS 42 22 00.00 40 Process Chillers and Coolers | Apr-2007 | R | Reference Update | |
Jan-2007 | N | UFGS 00 01 15 List of Drawings | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | N | UFGS 00 22 13 Supplementary Instructions to Bidders | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | N | UFGS 00 41 00 Bid Schedules | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | A | UFGS 01 32 01.00 10 Project Schedule | Jan-2007 | R | Added Design-Build tailoring option | |
Jan-2007 | N | UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) | Jan-2007 | R | Deleted [DESIGN BUILD] from the title and Design-Build requirements from the section. | |
Jan-2007 | N | UFGS 01 45 00.00 20 Quality Control | Jan-2007 | R | Removed reference to UFGS 01 99 00 in paragraph Commissioning (1.4.1) | |
Jan-2007 | N | UFGS 01 58 00 Project Identification | Jan-2007 | R | Revised link to NAVFAC logo | |
Jan-2007 | A | UFGS 01 74 19 Construction Waste Management and Disposal | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | S | UFGS 03 30 00.00 40 Cast-in-Place Concrete | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 03 41 33.00 40 Precast Structural Pretensioned Concrete | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 03 47 00.00 40 Site-Cast Concrete | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 05 51 00.00 40 Metal Stairs | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 07 16 19 Metallic Oxide Waterproofing | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | N | UFGS 07 22 00 Roof and Deck Insulation | Jan-2007 | R | Incorporated NASA requirements | |
Jan-2007 | S | UFGS 07 22 00.00 40 Roof and Deck Insulation | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | Jan-2007 | R | Title changed from Asphalt Built-Up Roofing; Incorporated NASA requirements; Superseding 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | |
Jan-2007 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | Jan-2007 | R | Incorporated NASA requirements | |
Jan-2007 | N | UFGS 07 60 00 Flashing and Sheet Metal | Jan-2007 | R | Incorporated NASA Requirements | |
Jan-2007 | N | UFGS 07 92 00 Joint Sealants | Jan-2007 | R | Incorporated NASA requirements | |
Jan-2007 | N | UFGS 08 11 73 Sliding Fire Doors | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | S | UFGS 08 13 73.00 40 Sliding Metal Doors | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 08 44 00.00 40 Curtain Wall and Glazed Assemblies | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | A | UFGS 09 30 00 Ceramic Tile, Quarry Tile, and Paver Tile | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | A | UFGS 09 65 00 Resilient Flooring | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | A | UFGS 09 68 00 Carpeting | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | N | UFGS 09 97 13.16 Interior Coating of Welded Steel Water Tanks | Jan-2007 | R | Extensive rewrite. | |
Jan-2007 | N | UFGS 09 97 13.17 Three Coat Epoxy Interior Coating of Welded Steel Petroleum Fuel Tanks | Jan-2007 | R | Extensive rewrite | |
Jan-2007 | N | UFGS 09 97 13.27 High Performance Coating for Steel Structures | Jan-2007 | R | Extensive rewrite | |
Jan-2007 | A | UFGS 10 21 13 Toilet Compartments | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | A | UFGS 12 50 00 Furniture Systems | Jan-2007 | R | Added sustainable design language | |
Jan-2007 | S | UFGS 13 50 00.00 40 Special Instrumentation | Jan-2007 | R | Section References (SRF) update | |
Feb-2007 | A | UFGS 21 30 00 Fire Pumps | Feb-2007 | R | INTERIM RELEASE: Corrected metric conversion | |
Jan-2007 | N | UFGS 22 00 00 Plumbing, General Purpose | Jan-2007 | R | Revised non-water use urinals | |
Jan-2007 | A | UFGS 22 04 00.00 10 Plumbing, Hospital | Jan-2007 | R | Added non-water using urinal | |
Oct-2006 | S | UFGS 23 00 00.00 40 Heating, Ventilating, and Air Conditioning | Oct-2006 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 23 03 00.00 20 Basic Mechanical Materials and Methods | Jan-2007 | R | No Nature of Change statement provided. | |
Jan-2007 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Jan-2007 | R | Added jacketing system | |
Feb-2007 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Feb-2007 | R | INTERIM RELEASE: Corrected permeability | |
Jan-2007 | S | UFGS 23 55 13.00 40 Fuel-Fired Duct Heaters | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems | Jan-2007 | R | Added note "Not for use in Navy projects" to paragraphs 'Piping for Steam and Condensate' (2.3) and 'Piping for High-Pressure Compressed-Air Systems' (2.4) | |
Jan-2007 | N | UFGS 23 81 47 Water-Loop and Ground-Loop Heat Pump Systems | Jan-2007 | R | Title changed from Vertical Ground-Coupled Heat Exchange Systems; Superseding UFGS 23 81 46.00 20 Water Source Heat Pump Systems (requirements incorporated) | |
Oct-2006 | S | UFGS 26 05 00.00 40 Common Work Results for Electrical | Oct-2006 | R | Section References (SRF) update | |
Jan-2007 | S | UFGS 26 05 13.00 10 Medium-Voltage Cables | Jan-2007 | R | Section References (SRF) update | |
Jan-2007 | N | UFGS 26 05 33 Dockside Power Connection Stations | Jan-2007 | R | Title changed from 480 V Pier Power Outlet Assemblies; No Nature of Change statement provided. |