Related Materials: Policy on UFGS Changes and Revisions
Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.
To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.
To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.
After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.
To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.
KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Jul-2006 | N | UFGS 01 91 00 Commissioning | Jul-2006 | N | New section | |
Jan-2008 | N | UFGS 03 30 00.00 20 Cast-in-Place Concrete | Jul-2006 | D | Superseded by UFGS 03 30 00 Cast-in-Place Concrete Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2006 | N | UFGS 03 30 00.00 20 Cast-in-Place Concrete | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 05 12 00 Structural Steel | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 05 30 00 Steel Decks | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 06 10 00 Rough Carpentry | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 07 24 00 Exterior Insulation and Finish Systems | Jul-2006 | R | Change in fiber reinforced cement sheathing board | |
Jul-2006 | N | UFGS 07 55 23 Ethylene Propylene Diene Monomer (EPDM) Roofing Membrane | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 07 92 00 Joint Sealants | Jul-2006 | R | Added NASA requirements and sustainable design requirements | |
Jul-2006 | N | UFGS 08 11 13 Steel Doors and Frames | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 08 11 16 Aluminum Doors and Frames | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 08 14 00 Wood Doors | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 08 36 13 Sectional Overhead Doors | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 08 51 13.00 20 Aluminum Windows | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 08 51 23 Steel Windows | Jul-2006 | R | Added NASA requirements and sustainable design requirements | |
Jul-2006 | N | UFGS 08 52 00 Wood Windows | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 08 53 00 Plastic Windows | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 08 71 00 Door Hardware | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 08 81 00 Glazing | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 09 23 00 Gypsum Plastering | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 09 29 00 Gypsum Board | Jul-2006 | R | Added NASA requirements and sustainable design requirements | |
Jul-2006 | N | UFGS 09 97 13.16 Interior Coating of Welded Steel Water Tanks | Jul-2006 | R | Minor corrections | |
Jul-2006 | N | UFGS 09 97 13.17 Three Coat Epoxy Interior Coating of Welded Steel Petroleum Fuel Tanks | Jul-2006 | R | Minor corrections | |
Jul-2006 | N | UFGS 09 97 13.27 High Performance Coating for Steel Structures | Jul-2006 | R | Minor corrections | |
Jul-2006 | N | UFGS 22 00 00 Plumbing, General Purpose | Jul-2006 | R | Added sustainable design requirements and Army and Navy options for No-water vs Non-water urinals | |
Jul-2006 | N | UFGS 23 30 13.00 20 Ductwork and Ductwork Accessories | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 34 16.00 20 Air Handling Units | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 35 19.00 20 Industrial Ventilation and Exhaust | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 52 33.03 20 Water-Tube Boilers, Oil/Gas or Oil | Jul-2006 | R | Section revised. | |
Jul-2006 | N | UFGS 23 52 43.00 20 Low Pressure Water Heating Boilers (Under 800,000 BTU/HR Output) | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems | Jul-2006 | R | Added NASA requirements | |
Jul-2006 | N | UFGS 23 66 00.00 20 Central Refrigeration Equipment for Air Conditioning | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 69 00.00 20 Refrigeration Equipment for Cold Storage | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 76 00.00 20 Evaporative Cooling System | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 81 00.00 20 Unitary Air Conditioning Equipment | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 23 81 23.00 20 Computer Room Air Conditioning Units | Jul-2006 | R | Section revised. | |
Jul-2006 | N | UFGS 23 81 46.00 20 Water Source Heat Pump Systems | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 26 00 00.00 20 Basic Electrical Materials and Methods | Jul-2006 | R | Section revised. | |
Jul-2006 | N | UFGS 26 23 00 Low Voltage Switchgear | Jul-2006 | R | Reference Update | |
Jul-2006 | N | UFGS 26 51 00 Interior Lighting | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 26 56 00 Exterior Lighting | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 05 33 Landscape Establishment | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 10 00 [Pervious] Bituminous Concrete Pavement | Jul-2006 | R | Title changed from BITUMINOUS CONCRETE PAVEMENT; Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 11 16.16 [Base Course for Rigid] [and Subbase Course for Flexible] [Subbase Course for Pervious] Paving | Jul-2006 | R | Title changed from [BASE COURSE FOR RIGID] [AND SUBBASE COURSE FOR FLEXIBLE] PAVING; Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 11 24 Graded Crushed Aggregate Base Course for [Pervious] [Flexible] Pavement | Jul-2006 | R | Title changed from GRADED CRUSHED AGGREGATE BASE COURSE FOR FLEXIBLE PAVEMENT; Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities | Jul-2006 | R | Title changed from PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE FACILITIES; Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 31 13.00 20 Chain Link Fences and Gates | Jul-2006 | R | Removed Y2K warranty requirements. | |
Jul-2006 | N | UFGS 32 84 24 Irrigation Sprinkler Systems | Jul-2006 | R | Added reference to UFGS Section 03 40 00.00 10 Plant-Precast Concrete Products for Below Grade Construction | |
Jul-2006 | N | UFGS 32 93 00 Exterior Plants | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 32 96 00 Transplanting Exterior Plants | Jul-2006 | R | Added sustainable design requirements | |
Jul-2006 | N | UFGS 33 11 00 Water Utility Distribution Piping | Jul-2006 | R | Added reference to UFGS Section 03 40 00.00 10 Plant-Precast Concrete Products for Below Grade Construction | |
Jul-2006 | N | UFGS 33 52 13 Exterior Fuel Distribution | Jul-2006 | R | Section revised. | |
Jul-2006 | N | UFGS 33 63 16 Exterior Shallow Trench Steam Distribution | Jul-2006 | R | Added reference to UFGS Section 03 40 00.00 10 Plant-Precast Concrete Products for Below Grade Construction | |
Jul-2006 | N | UFGS 33 71 01 Overhead Transmission and Distribution | Jul-2006 | N | New - Superseding UFGS 33 70 01.00 10 Electrical Distribution System, Aerial and UFGS 33 71 01.00 20 Overhead Transmission and Distribution | |
Jul-2006 | N | UFGS 33 71 02.00 20 Underground Electrical Distribution | Jul-2006 | R | Title changed from UNDERGROUND TRANSMISSION AND DISTRIBUTION; Added regional requirements | |
Jul-2006 | N | UFGS 35 59 13.14 20 Polymeric Piles | Jul-2006 | N | New section | |
Apr-2006 | N | UFGS 01 14 00 Work Restrictions | Apr-2006 | R | Various changes to incorporate Navy Regional requirements | |
Apr-2006 | N | UFGS 01 30 00 Administrative Requirements | Apr-2006 | R | Various changes to incorporate Navy Regional requirements | |
Apr-2006 | N | UFGS 01 35 13 Special Project Procedures | Apr-2006 | R | Deleted paragraph 3.2.4. | |
Apr-2006 | N | UFGS 05 12 00 Structural Steel | Apr-2006 | R | Added metric measurement to paragraph 3.2.1. | |
Apr-2006 | N | UFGS 07 42 13 Metal Wall Panels | Apr-2006 | R | Added English and metric tags throughout; added metric measurements when missing. | |
Apr-2006 | N | UFGS 07 52 00 Modified Bituminous Membrane Roofing | Apr-2006 | R | Added English and metric tags throughout. | |
Apr-2006 | N | UFGS 26 05 33 Dockside Power Connection Stations | Apr-2006 | R | Thorough revision of section; retitled (formerly 480 V PIER POWER OUTLET ASSEMBLIES) | |
Apr-2006 | N | UFGS 28 16 00.00 20 Basic Intrusion Detection System (IDS) | Apr-2006 | R | Requires conformance to DM 13.02 | |
Apr-2006 | N | UFGS 28 20 00.00 20 Electronic Security Systems (ESS) Commercial | Apr-2006 | R | Requires conformance to DM 13.02; retitled (formerly COMMERCIAL INTRUSION DETECTION SYSTEMS (IDS)) | |
Nov-2018 | N | UFGS 00 73 03 Supplementary Conditions for Azores Projects | Aug-2008 | D | Section is outdated and not used. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 02 82 00 Asbestos Remediation | Nov-2018 | N | Update to industry standards and unifying into one Tri-Service UFGS. Superseding UFGS 02 82 13.00 10 (Army) Asbestos Abatement and UFGS 02 82 16.00 20 (Navy) Engineering Control of Asbestos Containing Materials. | |
Nov-2018 | N | UFGS 02 82 16.00 20 Engineering Control of Asbestos Containing Materials | Aug-2011 | D | Superseded by UFGS 02 82 00 ASBESTOS REMEDIATION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 02 82 33.13 20 Removal/Control and Disposal of Paint with Lead | Aug-2011 | D | Superseded by UFGS 02 83 00 LEAD REMEDIATION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 02 83 00 Lead Remediation | Nov-2018 | N | Update to industry standards and unifying into one Tri-Service UFGS. Superseding UFGS 02 82 33.13 20 Removal/Control and Disposal of Paint with Lead (Navy), UFGS 02 83 13.00 20 Lead in Construction (Navy), and UFGS 02 83 19.13 10 Lead-Based Paint Abatement (Army). | |
Nov-2018 | N | UFGS 02 83 13.00 20 Lead in Construction | Aug-2011 | D | Superseded by UFGS 02 83 00 LEAD REMEDIATION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 02 85 00 Mold Remediation | Nov-2018 | N | Update to industry standards and unifying into one Tri-Service UFGS. Superseding UFGS 02 85 00.00 20 Mold Remediation. | |
Nov-2018 | N | UFGS 02 85 00.00 20 Mold Remediation | May-2011 | D | Superseded by UFGS 02 85 00 MOLD REMEDIATION. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 11 11 37 Electric Vehicle Supply Equipment | Nov-2018 | N | New section | |
Nov-2018 | N | UFGS 25 50 00.00 20 Cybersecurity of Facility-Related Control Systems | Feb-2017 | D | Navy-only Section, including NAVFAC Interim Technical Guidance (ITG 2017-01) – Application of Cybersecurity to Facility-Related Control Systems, is superseded by Tri-Service cybersecurity UFGS Section 25 05 11 Cybersecurity for Facility-Related Control Systems. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 31 21 13 Radon Mitigation | Nov-2018 | R | Periodic update. | |
Nov-2018 | N | UFGS 33 65 00 Cleaning Petroleum Storage Tanks | Aug-2011 | D | Superseded by UFGS 33 01 50.60 CLEANING OF PETROLEUM STORAGE TANKS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 33 09 52 Fuel Pump Control and Annunciation System (Non-Hydrant) | Nov-2018 | N | New section | |
Nov-2018 | N | UFGS 33 52 10 Fuel Systems Piping (Service Station) | Nov-2018 | R | Complete review and update including Section title change from SERVICE PIPING FUEL SYSTEMS; Preparing Activity changed from Army to Navy | |
Nov-2018 | N | UFGS 33 52 90.00 20 Welding for POL Service Piping | Feb-2010 | D | Superseded by UFGS 33 52 23.15 POL SERVICE PIPING WELDING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 33 56 13.13 Steel Tanks With Fixed Roofs | Aug-2015 | D | Superseded by UFGS 33 56 21.17 SINGLE WALL ABOVE GROUND FIXED ROOF STEEL POL STORAGE TANK. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 33 56 13.15 Undertank Interstitial Space | Aug-2015 | D | Superseded by UFGS 33 56 21.18 SINGLE WALL POL TANK UNDERTANK INTERSTITIAL SPACE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Nov-2018 | N | UFGS 00 22 13.00 20 Supplementary Instructions to Offerors | Feb-2014 | C | 3 | Deleted requirement for Azores excess shipping cost provisions. |
Nov-2018 | N | UFGS 01 14 00 Work Restrictions | Nov-2011 | C | 6 | Changed tailoring tags from NAVFAC PAC to NAVFAC HI based on CCRs, removed outdated information for Naval Shipyard Pearl Harbor, HI, and added personnel security requirements for use in secure or controlled areas. |
Nov-2018 | N | UFGS 01 32 17.00 20 Cost-Loaded Network Analysis Schedules (NAS) | May-2018 | C | 1 | Corrected notes and paragraphs, for DB and DBB, on Baseline NAS submittals and requirements. |
Nov-2018 | N | UFGS 03 30 00 Cast-In-Place Concrete | May-2014 | C | 4 | Added note to use UFGS 03 31 29 or UFGS 03 31 30 in ESC C4 and C5 locations or where deicing salts. |
Nov-2018 | N | UFGS 03 31 29 Marine Concrete with Service Life Modeling | Aug-2012 | C | 2 | Added notes to direct use of this section and Type II and V Portland cement in ESC C4 and C5 locations and where deicing salts used on structure, note for coral aggregates, and note for water reducing. |
Nov-2018 | N | UFGS 05 12 00 Structural Steel | Aug-2018 | C | 1 | Added note for shop primer requirements in exterior locations or areas open to the exterior. |
Nov-2018 | N | UFGS 06 10 00 Rough Carpentry | Aug-2016 | C | 2 | Added notes for requirement of preservative treatment and hot-dip galvanized rough hardware in ESC C3 thru C5 and humid locations, and not to use particle board or OSB in C4 and C5 and humid locations. |
Nov-2018 | N | UFGS 06 20 00 Finish Carpentry | Aug-2016 | C | 2 | Added notes to not use particleboard or hardboard siding in humid or ESC C4 and C5 locations. |
Nov-2018 | N | UFGS 07 22 00 Roof and Deck Insulation | Feb-2016 | C | 3 | Added notes to consider use of polystyrene as a roof insulation in humid or ESC C3-C5 locations and not to use wood fiberboard in humid or ESC C4-C5 locations. |
Nov-2018 | N | UFGS 07 41 13 Metal Roof Panels | May-2011 | C | 2 | Added notes for gauge requirements of Aluminum and Steel Sheet Panels in humid and ESC C3-C5 locations. |
Nov-2018 | N | UFGS 07 51 13 Built-Up Asphalt Roofing | May-2012 | C | 2 | Added notes restricting use of coral gravel in humid and ESC C3-C5 locations and gravel surface cap sheet in humid and ESC C4-C5 locations. |
Nov-2018 | N | UFGS 07 60 00 Flashing and Sheet Metal | May-2017 | C | 2 | Added notes for flashing requirements, lead sheet, thickness of aluminum alloy sheet and plate, and fasteners in humid or ESC C3-C5 locations and nailing in ESC C4-C5 locations. |
Nov-2018 | N | UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing | Aug-2016 | C | 2 | Added note for use of coated alclad in ESC C3-C5 locations. |
Nov-2018 | N | UFGS 07 92 00 Joint Sealants | Aug-2016 | C | 3 | Added sealant requirements with ambient temperatures that exceed 43.33 degrees C (110 degrees F). |
Nov-2018 | N | UFGS 08 11 13 Steel Doors and Frames | Feb-2010 | C | 3 | Added note for door louvers and exterior screens in humid or ESC C3-C5 locations. |
Nov-2018 | N | UFGS 08 11 16 Aluminum Doors and Frames | May-2017 | C | 2 | In paragraph "Finishes," defined corrosive atmospheres in terms of ISO 9223 ESC C3-C5, and humid locations in terms of ASHRAE 90.1. |
Nov-2018 | N | UFGS 08 51 13 Aluminum Windows | May-2011 | C | 4 | Added note for finish requirements in humid and ESC C3-C5 locations. |
Nov-2018 | N | UFGS 08 51 23 Steel Windows | Aug-2011 | C | 4 | Added note restricting use of steel windows in humid and ESC C3-C5 locations. |