Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Feb-2011 | S | UFGS 42 22 16 Reciprocating Process Chillers and Coolers | May-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 42 22 16.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | S | UFGS 42 23 13 Process Condensers | May-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 42 23 13.00 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | S | UFGS 43 41 16.16 Vertical Atmospheric Tanks and Vessels | Aug-2010 | D | NASA reclassified this as fifth level; Renumbered/ Superseded by UFGS 43 41 16.16 40 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 11 33 Thermal (Catalytic) Oxidation Systems | Oct-2007 | D | Superseded by UFGS 44 13 52 Thermal (Catalytic) Oxidation Systems without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 41 13 Prefabricated Biochemical Wastewater Treatment Plant | Oct-2007 | D | Superseded by UFGS 46 07 53.16 Packaged Wastewater Treatment Equipment, Biochemical without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 41 13.19 Composting Toilet | Apr-2006 | D | Superseded by UFGS 46 07 53.19 Composting Toilet without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 42 13.00 10 Air Supply and Diffusion Equipment for Sewage Treatment | Apr-2006 | D | Superseded by UFGS 46 51 00.00 10 Air and Gas Diffusion Equipment without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | N | UFGS 44 42 13.00 20 Aeration Equipment | Nov-2009 | D | Superseded by UFGS 46 07 53.13 Packaged Wastewater Treatment Equipment, Aeration without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | N | UFGS 44 42 23 Circular Clarifier | Nov-2009 | D | Superseded by UFGS 46 43 21 Circular Clarifier Equipment without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 42 26 Comminutor | Apr-2006 | D | Superseded by UFGS 46 24 16 Comminutors without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | N | UFGS 44 42 39 Grit Collecting Equipment | Nov-2009 | D | Superseded by UFGS 46 23 00 Grit Removal and Handling Equipment without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | N | UFGS 44 42 53 Parallel Plate [or Vertical Tube] Gravity Oil-Water Separator | Apr-2006 | D | Superseded by UFGS 46 25 14 Coalescing [or Vertical Tube] Oil-Water Separators without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 42 59 Continuous Loop Reactor Wastewater Treatment System | Apr-2006 | D | Superseded by UFGS 46 53 62 Continuous Loop Reactor Wastewater Treatment System without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 43 00 Filtration System | Oct-2007 | D | Superseded by UFGS 46 61 00 Filtration Equipment without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | N | UFGS 44 44 46 Hydrotherapy Equipment | Apr-2006 | D | Superseded by UFGS 13 17 43 Hydrotherapy Equipment without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 44 53 Advanced Oxidation Processes (AOP) | Oct-2007 | D | Superseded without revision by UFGS 46 30 13 Advanced Oxidation Processes (AOP) to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 44 73 Ultraviolet Disinfection Equipment | Apr-2006 | D | Superseded by UFGS 46 66 56 Open-Channel Disinfection Equipment without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 46 00 Pumps; Sewage and Sludge | Apr-2006 | D | Superseded by UFGS 22 13 29 Sanitary Sewerage Pumps without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 46 13 Sludge-Collecting Equipment | Apr-2006 | D | Superseded by UFGS 46 71 16 Gravity Belt Thickeners without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 46 16 Recessed Chamber Filter Press System | Apr-2006 | D | Superseded by UFGS 46 76 23.16 Recessed Chamber Filter Presses without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 46 19 Sludge-Digester Gas, Heating, and Mixing System | Oct-2007 | D | Superseded by UFGS 46 73 00.35 Sludge-Digester Gas, Heating, and Mixing System without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Feb-2011 | A | UFGS 44 46 20 Floating Cover for Sludge-Digestion Tanks | Apr-2006 | D | Superseded by UFGS 46 73 40 Floating Cover for Sludge-Digestion Tanks without revision to comply with MF 2010 Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 05 59 13 Fabrication of Hydraulic Steel Structures | Aug-2009 | D | Superseded by UFGS 05 59 20 FABRICATION OF HYDRAULIC STEEL STRUCTURES. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 33 01 50.01 Cleaning Fuel Storage Tanks | Feb-2010 | D | Cancelled and replaced by existing UFGS 33 65 00 CLEANING PETROLEUM STORAGE TANKS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 02 01 50 Operation, Maintenance and Process Monitoring for Soil Vapor Extraction (SVE) Systems | May-2010 | D | Superseded by UFGS 02 62 16.13 10 OPERATION, MAINTENANCE AND PROCESS MONITORING FOR SOIL VAPOR EXTRACTION (SVE) SYSTEMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 11 24 27 Air Stripper | Oct-2007 | D | Superseded by UFGS 02 62 13.00 10 AIR AND STEAM STRIPPING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 02 62 16 Commissioning and Demonstration for Soil Vapor Extraction (SVE) Systems | Feb-2010 | D | Superseded by UFGS 02 62 16.16 10 COMMISSIONING AND DEMONSTRATION FOR SOIL VAPOR EXTRACTION (SVE) SYSTEMS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 33 34 13 Siphons, Dosing | Apr-2008 | D | Superseded by UFGS 33 34 56.00 10 DRAINAGE FIELD DOSING CHAMBERS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 33 34 00 Force Mains and Inverted Siphons; Sewer | Apr-2008 | D | Superseded by UFGS 33 31 23.00 10 SANITARY SEWER FORCE MAIN PIPING. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | A | UFGS 43 31 13.14 Downflow Liquid Activated Carbon Adsorption Units | Oct-2007 | D | Superseded by UFGS 43 31 13.13 10 ACTIVATED CARBON-GAS AND LIQUID PURIFICATION FILTERS. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Aug-2018 | N | UFGS 33 05 16 Concrete Poles | Aug-2008 | D | Concrete poles are covered in UFGS 03 45 33 PRECAST[ PRESTRESSED] STRUCTURAL CONCRETE. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | S | UFGS 01 31 19.00 40 | Apr-2006 | D | Redundant, section deleted. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | N | UFGS 01 50 00.00 20 Temporary Facilities and Controls | Apr-2006 | D | Superseded by UFGS 01 50 00 Temporary Construction Facilities and Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | S | UFGS 01 50 00.00 40 Temporary Facilities and Controls | Apr-2006 | D | Superseded by UFGS 01 50 00 Temporary Construction Facilities and Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | A | UFGS 01 50 02.00 10 Temporary Construction Facilities | Apr-2006 | D | Superseded by UFGS 01 50 00 Temporary Construction Facilities and Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | A | UFGS 10 22 26 Operable Partitions | Apr-2006 | D | Superseded by UFGS 10 22 26.33 Folding Panel Partitions and UFGS 10 22 26.43 Sliding Partitions. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | N | UFGS 23 30 13.00 20 Ductwork and Ductwork Accessories | Jul-2006 | D | Superseded by UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | N | UFGS 23 34 16.00 20 Air Handling Units | Jul-2006 | D | Superseded by UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | N | UFGS 26 32 33.00 20 Installation of Uninterruptible Power Supply (UPS) | Apr-2006 | D | Superseded by UFGS 26 33 53.00 20 Uninterruptible Power Supply (UPS). Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | A | UFGS 32 13 14 Concrete Pavement for Small Projects | Apr-2006 | D | Replaced/Superseded by UFGS 32 13 13.03 Airfields and Heavy Duty Concrete Pavement Less Than 10000 Cubic Yards. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | A | UFGS 33 51 01.00 10 Gas Piping Systems | Apr-2006 | D | Renamed/Superseded by UFGS 23 11 23.00 10 with same title. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 01 60 00.00 40 Product Requirements | Apr-2006 | D | Redundant, section deleted. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | A | UFGS 05 05 23.00 14 Welding, Structural | Jul-2006 | D | Superseded by / Renumbered to UFGS 05 05 23 Welding, Structural Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | N | UFGS 05 21 00.00 20 Steel Joists[ and Joist Girders] | Apr-2006 | D | Superseded by UFGS 05 21 13 Deep Longspan Steel Joist Framing, UFGS 05 21 16 Longspan Steel Joist Framing, UFGS 05 21 19 Open Web Steel Joist Framing, and UFGS 05 21 23 Steel Joist Girder Framing Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | A | UFGS 05 21 02.00 10 Steel Joists | Apr-2006 | D | Superseded by UFGS 05 21 13 Deep Longspan Steel Joist Framing, UFGS 05 21 16 Longspan Steel Joist Framing, UFGS 05 21 19 Open Web Steel Joist Framing, and UFGS 05 21 23 Steel Joist Girder Framing Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 05 70 00.00 40 Decorative Metals | Apr-2007 | D | Superseded by UFGS 05 72 00 Decorative Metal Specialties Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | A | UFGS 08 33 13.00 14 Metal Rolling Counter Doors | Jul-2006 | D | Renumbered/Superseded by UFGS 08 33 13 Metal Rolling Counter Doors Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | A | UFGS 08 33 23 Overhead Coiling Doors | Apr-2006 | D | Section superseded by NASA prepared UFGS 08 33 23 Overhead Coiling Doors; Army title of UFGS 08 33 23 was OVERHEAD ROLLING DOORS Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 08 33 23.00 40 Overhead Coiling Doors | Jun-2006 | D | Superseded by UFGS 08 33 23 Overhead Coiling Doors Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 09 23 82.00 40 Fireproof Gypsum Plastering | Jul-2007 | D | Superseded by 09 23 82 Fireproof Gypsum Plastering Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 09 30 16.00 40 Quarry Tiling | Apr-2007 | D | Superseded by UFGS 09 30 00 Ceramic Tile, Quarry Tile and Paver Tile Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 10 51 00.00 40 Lockers | Apr-2007 | D | Unified with/Superseded by UFGS 10 51 13 Metal Lockers Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | A | UFGS 12 20 00 Window Treatment | Jul-2006 | D | Superseded by UFGS 12 21 00 Window Blinds, UFGS 12 22 00 Curtains and Drapes, and UFGS 12 24 13 Roller Window Shades Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | N | UFGS 12 22 00.00 20 Curtains and Drapes | Apr-2006 | D | Superseded by UFGS 12 22 00 Curtains and Drapes Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | A | UFGS 14 20 00 Elevators, Electric | Apr-2006 | D | Superseded by UFGS 14 21 13 Electric Traction Freight Elevators and UFGS 14 21 23 Electric Traction Passenger Elevators Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | N | UFGS 14 21 00.00 20 Electric Traction Elevators | Apr-2006 | D | This section is scheduled for deletion in the October 2007 release. It is superseded by UFGS 14 21 13 Electric Traction Freight Elevators and UFGS 14 21 23 Electric Traction Passenger Elevators. NOTE: THIS SECTION WAS NOT DELETED FROM THE DATABASE AT THAT TIME AND REMAINED UNTIL 2016. | |
Jul-2007 | F | UFGS 23 14 00 Commissioning of Fuel Facility Systems | Apr-2007 | D | Superseded by UFGS 33 08 55 Commissioning of Fuel Facility Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jul-2007 | S | UFGS 26 18 39.00 40 Medium-Voltage Controllers | Jan-2007 | D | Renamed to/Superseded by UFGS 26 60 13 Low Voltage Motors Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | N | UFGS 33 32 16.13 Package [Grinder Pump] [Lift] Station | Apr-2006 | D | Superseded by UFGS 33 32 13.13 Packaged Sewage Lift Stations, Grinder Pump Type Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 33 40 00.00 40 Storm Drainage Utilities | Apr-2007 | D | Renumbered/Superseded by UFGS 33 40 00 Storm Drainage Utilities Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | S | UFGS 07 22 00.00 40 Roof and Deck Insulation | Jan-2007 | D | Superseded by UFGS 07 22 00 Roof and Deck Insulation (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | S | UFGS 08 80 00.00 40 Glazing | Oct-2006 | D | Superseded by UFGS 08 81 00 Glazing Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | A | UFGS 09 69 00 Access Flooring | Apr-2006 | D | Superseded by UFGS 09 69 13 Rigid Grid Access Flooring and UFGS 09 69 19 Stringerless Access Flooring Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | S | UFGS 09 69 00.00 40 Access Flooring | Jun-2006 | D | Superseded by UFGS 09 69 13 Rigid Grid Access Flooring and UFGS 09 69 19 Stringerless Access Flooring Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | S | UFGS 14 24 00.00 40 Hydraulic Elevators | Jun-2006 | D | Superseded by UFGS 14 24 00 Hydraulic Elevators (Preparing Activity: USACE) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | N | UFGS 26 11 13 Secondary Unit Substations | Apr-2006 | D | Superseded by UFGS 26 11 16 Secondary Unit Substations Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | N | UFGS 26 11 16.00 20 Primary Unit Substations | Apr-2006 | D | Superseded by UFGS 26 11 13.00 20 Primary Unit Substations Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | A | UFGS 33 56 17 Tightness Testing of Existing Underground Fuel Systems | Apr-2006 | D | Superseded by UFGS 33 59 00 Tightness Testing of Existing Underground Fuel Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Apr-2007 | S | UFGS 33 71 49 23.40 Underground Medium Voltage Wiring | Jan-2007 | D | Superseded by UFGS 33 71 02.00 20 Underground Electrical Distribution Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 02 41 00.00 40 Demolition | Jun-2006 | D | Superseded by UFGS 02 41 00 [Demolition][ and ][Deconstruction] (Preparing Activity: Army) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 05 21 00.00 40 Steel Joist Framing | Oct-2006 | D | Information already provided in UFGS 05 21 00.00 20 Steel Joists[ and Joist Girders] and UFGS 05 21 02.00 10 Steel Joists Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 05 50 00.00 40 Metal Fabrications | Oct-2006 | D | Information already provided in UFGS Sections 05 50 00 Metal Fabrications, 05 50 03.00 10 Metalwork Fabrication, Machine Work, Miscellaneous Provisions, and 05 50 04.00 10 Metals: Miscellaneous, Standard Article, Shop Fabricated Items for Civil Works Structures. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 07 51 13.13 40 Cold Applied Built-Up Asphalt Roofing | Oct-2006 | D | Superseded by 07 51 13 Built-Up Asphalt Roofing (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 07 52 00.00 40 Modified Bituminous Membrane Protection | Oct-2006 | D | Superseded by UFGS 07 52 00 Modified Bituminous Membrane Roofing (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 07 53 00.00 40 Elastomeric Membrane Roofing | Oct-2006 | D | Superseded by UFGS 07 53 23 Ethylene-Propylene-Diene Monomer Roofing (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | N | UFGS 07 55 23 Ethylene Propylene Diene Monomer (EPDM) Roofing Membrane | Jul-2006 | D | Superseded by UFGS 07 53 23 Ethylene-Propylene-Diene Monomer Roofing Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 07 60 00.00 40 Flashing and Sheet Metal | Oct-2006 | D | Superseded by UFGS 07 60 00 Flashing and Sheet Metal (Preparing Activity: Navy) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 10 22 00.00 40 Partitions | Jun-2006 | D | Information already provided in UFGS 10 22 13 Wire Mesh Partitions, UFGS 10 22 19 Demountable and Movable Partitions, UFGS 10 22 26 Operable Partitions, and UFGS 10 22 26.13 Accordion Folding Partitions Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 10 22 13.00 40 Wire Mesh Partitions | Apr-2006 | D | Information already provided in UFGS 10 22 13 Wire Mesh Partitions Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 10 22 19.53 40 Demountable Gypsum Partitions | Jun-2006 | D | Information already provided in UFGS 10 22 19 Demountable Movable Partitions Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 10 22 26.13 40 Accordion-Folding Partitions | Oct-2006 | D | Information already provided in UFGS 10 22 26 Operable Partitions and UFGS 10 22 26.13 Accordion Folding Partitions Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 11 13 19.13 40 Loading Dock Levelers | Jun-2006 | D | Superseded by UFGS 11 13 10 Dock Levelers Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 14 21 00.00 40 Electric Traction Elevators | Oct-2006 | D | Information already provided in UFGS 14 20 00 Elevators, Electric and UFGS 14 21 00.00 20 Electric Traction Elevators Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 22 00 00.00 40 Plumbing | Jun-2006 | D | Superseded by UFGS 22 00 00 Plumbing, General Purpose Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 22 41 00.00 40 Residential Plumbing Fixtures | Oct-2006 | D | Superseded by UFGS 22 42 00.00 40 Commercial Plumbing Fixtures Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | N | UFGS 23 09 54.00 20 Direct Digital Control Systems | Apr-2006 | D | Superseded by UFGS 23 09 23.13 20 BACnet Direct Digital Control Systems for HVAC Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 23 61 00.00 40 Refrigerant Compressors | Jun-2006 | D | Information already provided in the following sections: UFGS 23 63 00.00 10 Cold Storage Refrigeration Systems, 23 66 00.00 20 Central Refrigeration Equipment For Air Conditioning, 23 69 00.00 20 Refrigeration Equipment For Cold Storage, and 23 82 02.00 10 Unitary Heating Cooling Equipment Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 23 73 00.00 40 Indoor Central-Station Air-Handling Units | Jun-2006 | D | Information already provided in UFGS 23 34 16.00 20 Air Handling Units Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 23 73 33.00 40 Indoor Indirect Fuel-Fired Heating and Ventilating Units | Jun-2006 | D | Information already provided in UFGS 23 82 01.00 10 Warm Air Heating Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 23 81 23.00 40 Computer-Room Air-Conditioners | Jun-2006 | D | Information already provided in UFGS 23 81 23.00 20 Computer Room Air Conditioning Units Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | N | UFGS 23 81 46.00 20 Water Source Heat Pump Systems | Jul-2006 | D | Superseded by UFGS 23 81 47 Water-Loop and Ground-Loop Heat Pump Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 26 00 00.00 40 Electrical | Oct-2006 | D | Information already provided in UFGS 26 05 00.00 40 Common Work Results for Electrical and UFGS 26 00 00.00 20 Basic Electrical Materials and Methods Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 26 11 13.00 40 Primary Unit Substations | Jun-2006 | D | Information already provided in UFGS 26 11 16.00 20 Primary Unit Substations Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 26 11 16.00 40 Secondary Unit Substations | Jun-2006 | D | Information already provided in UFGS 26 11 13 Secondary Unit Substations Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 26 42 00.00 40 Cathodic Protection | Jun-2006 | D | Information already provided in UFGS 26 42 14.00 10 Cathodic Protection System (Sacrificial Anode) Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 26 42 19.00 40 Cathodic Protection, Impressed Current | Jun-2006 | D | Information already provided in UFGS 26 42 19.00 20 Cathodic Protection by Impressed Current Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 33 16 13.13 40 Steel Aboveground Water Utility Storage Tanks | Jun-2006 | D | Information already provided in UFGS 33 16 15 Water Storage Steel Tanks Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 33 50 00.00 40 Fuel Distribution Utilities | Oct-2006 | D | Information already provided in UFGS 33 51 00.00 20 Natural Gas Distribution, UFGS 33 51 01.00 10 Gas Piping Systems, and UFGS 33 51 03.00 10 Gas Distribution System Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 41 22 00.00 40 Cranes and Hoists | Oct-2006 | D | Information already provided in UFGS 41 22 13.13 20 Cranes, Overhead Electric, Top Running (Under 20,000 Pounds) and UFGS 41 22 13.14 20 Cranes, Overhead Electric, Underrunning Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2007 | S | UFGS 41 22 23.19 40 Monorail Hoists | Oct-2006 | D | Information already provided in the following sections: UFGS 41 22 23.19 10 Monorails with Electric, Air, or Manual Powered Hoist, UFGS 41 22 03.13 20 Monorails with Manual Hoists, UFGS 41 22 03.16 20 Monorails with Air Motor Powered Hoists, and UFGS 41 22 03.19 20 Monorails with Electric Powered Hoists Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. |