Unified Facilities Guide Specifications (UFGS)  Subscribe to Unified Facilities Guide Specifications (UFGS)

UFGS Master Updated February 13, 2024; Posted February 22, 2024

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (HQ AFCEC). UFGS are for use in specifying construction for the military services.

On September 30, 2023, NASA officially withdrew from the UFGS program. All NASA-specific UFGS sections (40) have been removed from the UFGS Master, though some UFGS sections may still include a NASA section reference. The final NASA UFGS Master is available on the WBDG at NASA UFGS Master Specifications.

The Unified Facilities Guide Specifications (UFGS) are published only in electronic format and are intended to be used with SpecsIntact software. The UFGS Master complies with UFC 1-300-02. SpecsIntact supports the UFGS format. SpecsIntact can still open Masters or Jobs created with older versions of the UFGS format.

Updated UFGS are posted quarterly in February, May, August, and November.

UFGS that have been unified for use by all participating agencies have a level 3 or level 4 Section number. The UFGS uses level 5 to identify a single-agency specification. The number "10" is used by USACE, "20" by NAVFAC, and "30" by AFCEC. The order of precedence for selecting UFGS sections for a project is generally:

  1. Regional UFGS if required by the contract or published on WBDG
  2. Single-agency UFGS for whom project is being developed
  3. Unified UFGS
  4. UFGS identified as specific to another DoD Service (for DoD projects only)

Points of contact and procedures for the development and maintenance of UFGS documents are prescribed in the latest edition of MIL-STD-3007.

The UFGS Section Template is now provided in the UFGS Master with each quarterly release and can be found under Tools in the SpecsIntact Explorer.

SpecsIntact for NMCI Users

Questions, comments, suggestions and recommended changes for guide specifications should be submitted as a Criteria Change Request (CCR). To submit, click on the CCR link next to the document title (below). CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal, or after a project award. Questions or interpretations pertaining to these documents or situations should be referred to the Contracting Officer.

Click the 'Title' or 'Date' heading to sort by ascending or descending order. Narrow the list by selecting a 'Division' option from the drop-down or view archived documents by selecting from the 'Status' drop-down and clicking 'Apply'.

Active documents are available in the following formats:   SpecsIntact (SEC) in compressed ZIP  |   Adobe Acrobat (PDF)

Archived release files are available in  Adobe Acrobat (PDF) in compressed ZIP

  Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

Title Datesort descending View CCR
UFGS 46 43 21 Circular Clarifier Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 46 23 00 Grit Removal and Handling Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 32 32 23.13 Segmental Concrete Block Retaining Wall   02-01-2020  PDF |  ZIP  CCR
UFGS 33 01 50.31 Leak Detection For Fueling Systems   02-01-2020  PDF |  ZIP  CCR
UFGS 23 75 15 Custom-Packaged, Aircraft Pre-Conditioned Air Units   02-01-2020  PDF |  ZIP  CCR
UFGS 23 81 29 Variable Refrigerant Flow HVAC Systems   02-01-2020  PDF |  ZIP  CCR
UFGS 46 07 53 Packaged Wastewater Treatment Equipment   02-01-2020  PDF |  ZIP  CCR
UFGS 09 97 02 Painting: Hydraulic Structures   02-01-2020  PDF |  ZIP  CCR
UFGS 26 29 23 Adjustable Speed Drive (ASD) Systems Under 600 Volts   02-01-2020  PDF |  ZIP  CCR
UFGS 23 52 30.01 10 Central Coal-Fired Steam-Generating System   05-01-2020  PDF |  ZIP  CCR
UFGS 23 52 30.02 10 Central Steam Generating System - Combination Gas and Oil Fired   05-01-2020  PDF |  ZIP  CCR
UFGS 23 58 00.00 10 Central Steam Heating and Utilities Systems   05-01-2020  PDF |  ZIP  CCR
UFGS 23 80 20.00 10 Gas-Fired Heating Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 26 32 15.00 Engine-Generator Set Stationary 15-2500 kW, with Auxiliaries   05-01-2020  PDF |  ZIP  CCR
UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads and Site Facilities   05-01-2020  PDF |  ZIP  CCR
UFGS 22 60 70 Gas and Vacuum Systems for Healthcare Facilities   05-01-2020  PDF |  ZIP  CCR
UFGS 26 36 23 Automatic Transfer Switches and By-Pass/Isolation Switch   05-01-2020  PDF |  ZIP  CCR
UFGS 11 70 00 General Requirements for Medical and Dental Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 32 13 43 Pervious Concrete Paving   05-01-2020  PDF |  ZIP  CCR
UFGS 27 53 19.13 First Responder Distributed Antennae Systems (DAS)   05-01-2020  PDF |  ZIP  CCR
UFGS 11 72 13 Medical Equipment, Miscellaneous   05-01-2020  PDF |  ZIP  CCR
UFGS 41 22 23.19 Monorail Hoists   05-01-2020  PDF |  ZIP  CCR
UFGS 33 46 13 Foundation Drainage   05-01-2020  PDF |  ZIP  CCR
UFGS 32 11 13.16 Bituminous-Stabilized Subgrade   05-01-2020  PDF |  ZIP  CCR
UFGS 11 71 00 Sterilizers and Associated Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 11 82 19 Packaged Incinerators   05-01-2020  PDF |  ZIP  CCR
UFGS 33 56 53 Compressed Gases Storage Tanks   05-01-2020  PDF |  ZIP  CCR
UFGS 32 11 26.19 Bituminous-Stabilized Base and Subbase Courses   05-01-2020  PDF |  ZIP  CCR
UFGS 13 17 43 Hydrotherapy Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 32 11 33.13 Portland Cement-Stabilized Base Courses   05-01-2020  PDF |  ZIP  CCR
UFGS 26 51 00 Interior Lighting   05-01-2020  PDF |  ZIP  CCR
UFGS 22 00 70 Plumbing for Healthcare Facilities   05-01-2020  PDF |  ZIP  CCR
UFGS 40 60 00 Process Control   05-01-2020  PDF |  ZIP  CCR
UFGS 32 11 26 Hot-Mix Bituminous Base Course for Roads and Streets   05-01-2020  PDF |  ZIP  CCR
UFGS 43 11 00.10 Off-Gas Fans, Blowers and Pumps   05-01-2020  PDF |  ZIP  CCR
UFGS 32 01 17.62 Paving Fabric Interlayer   05-01-2020  PDF |  ZIP  CCR
UFGS 23 11 20 Facility Gas Piping   05-01-2020  PDF |  ZIP  CCR
UFGS 44 13 10.13 Vapor Phase Activated Carbon Adsorption Units   05-01-2020  PDF |  ZIP  CCR
UFGS 27 51 16 Public Address Systems   05-01-2020  PDF |  ZIP  CCR
UFGS 23 30 00 HVAC Air Distribution   05-01-2020  PDF |  ZIP  CCR
UFGS 44 13 51 Thermal Oxidation Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 23 35 16.17 10 Mechanical Engine [and Welding Fume] Exhaust Systems   05-01-2020  PDF |  ZIP  CCR
UFGS 27 05 13.43 Television Distribution System   05-01-2020  PDF |  ZIP  CCR
UFGS 11 74 00 Dental Equipment   05-01-2020  PDF |  ZIP  CCR
UFGS 23 52 30.00 10 Heat Recovery Boilers   05-01-2020  PDF |  ZIP  CCR
UFGS 10 14 00.20 Interior Signage   08-01-2020  PDF |  ZIP  CCR
UFGS 21 13 16 Dry Pipe Sprinkler Systems, Fire Protection   08-01-2020  PDF |  ZIP  CCR
UFGS 08 60 45 [Skylights] [ and ] [Translucent Panels]   08-01-2020  PDF |  ZIP  CCR
UFGS 21 13 18 Preaction Sprinkler Systems, Fire Protection   08-01-2020  PDF |  ZIP  CCR
UFGS 08 91 00 Metal [Wall] [and] [Door] Louvers   08-01-2020  PDF |  ZIP  CCR
UFGS 21 13 19 Deluge Sprinkler Systems, Fire Protection   08-01-2020  PDF |  ZIP  CCR
UFGS 28 31 60 Interior Fire Alarm System, Non-Addressable   08-01-2020  PDF |  ZIP  CCR
UFGS 28 31 66 Interior Fire Alarm And Mass Notification System, Non-Addressable   08-01-2020  PDF |  ZIP  CCR
UFGS 08 56 53 Blast Resistant Tempered Glass Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 06 61 16 Solid Surfacing Fabrications   08-01-2020  PDF |  ZIP  CCR
UFGS 28 31 70 Interior Fire Alarm System, Addressable   08-01-2020  PDF |  ZIP  CCR
UFGS 22 33 30.00 10 Solar Water Heating Equipment   08-01-2020  PDF |  ZIP  CCR
UFGS 08 11 13 Steel Doors and Frames   08-01-2020  PDF |  ZIP  CCR
UFGS 44 41 00 Water Pollution Containment And Cleanup Equipment   08-01-2020  PDF |  ZIP  CCR
UFGS 08 11 73 Sliding Fire Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 35 01 41.00 10 Electromechanical Operating Machinery for Locks and Dams   08-01-2020  PDF |  ZIP  CCR
UFGS 08 32 13 Aluminum Sliding Glass Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 10 21 13 Toilet Compartments   08-01-2020  PDF |  ZIP  CCR
UFGS 35 05 40.17 Self-Lubricated Materials, Fabrication, Handling, and Assembly   08-01-2020  PDF |  ZIP  CCR
UFGS 08 33 23 Overhead Coiling Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 10 22 39 Folding Panel Partitions   08-01-2020  PDF |  ZIP  CCR
UFGS 35 20 23 Dredging   08-01-2020  PDF |  ZIP  CCR
UFGS 08 36 13 Sectional Overhead Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 10 26 00 Wall and Door Protection   08-01-2020  PDF |  ZIP  CCR
UFGS 35 42 34 Reinforced Soil Slope   08-01-2020  PDF |  ZIP  CCR
UFGS 13 34 19 Metal Building Systems   08-01-2020  PDF |  ZIP  CCR
UFGS 08 36 19 Vertical Lift Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 10 28 13 Toilet Accessories   08-01-2020  PDF |  ZIP  CCR
UFGS 08 51 23 Steel Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 12 24 13 Roller Window Shades   08-01-2020  PDF |  ZIP  CCR
UFGS 09 30 10 Ceramic, Quarry, and Glass Tiling   08-01-2020  PDF |  ZIP  CCR
UFGS 08 51 69.10 Aluminum Storm Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 12 61 13 Upholstered Audience Seating   08-01-2020  PDF |  ZIP  CCR
UFGS 09 51 00 Acoustical Ceilings   08-01-2020  PDF |  ZIP  CCR
UFGS 28 31 76 Interior Fire Alarm and Mass Notification System, Addressable   08-01-2020  PDF |  ZIP  CCR
UFGS 08 52 00 Wood Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 10 11 00 Visual Display Units   08-01-2020  PDF |  ZIP  CCR
UFGS 21 13 13 Wet Pipe Sprinkler Systems, Fire Protection   08-01-2020  PDF |  ZIP  CCR
UFGS 08 53 00 Plastic Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 31 41 16 Metal Sheet Piling   11-01-2020  PDF |  ZIP  CCR
UFGS 25 08 11.00 20 Risk Management Framework for Facility-Related Control Systems   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 13.26 Pressure-Injected Footings   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 16.13 Steel Pipe Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 01 30 00 Administrative Requirements   11-01-2020  PDF |  ZIP  CCR
UFGS 31 63 16 Augered Cast-In-Place Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 50 Densified Aggregate Piers   11-01-2020  PDF |  ZIP  CCR
UFGS 31 68 13 Soil and Rock Anchors   11-01-2020  PDF |  ZIP  CCR
UFGS 31 63 26.60 [Grouted] Helical Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 01 35 26 Governmental Safety Requirements   11-01-2020  PDF |  ZIP  CCR
UFGS 13 49 21 Radio Frequency (RF) Shielding: Magnetic Resonance Imaging (MRI)   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 13.20 Precast/Prestressed Concrete Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 23 Piling: Composite, Wood And Cast In-Place Concrete   11-01-2020  PDF |  ZIP  CCR
UFGS 01 35 13 Special Project Procedures   11-01-2020  PDF |  ZIP  CCR
UFGS 32 12 15.13 Asphalt Paving for Airfields   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 13.24 Concrete Cylinder Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 32 12 16.16 Road-Mix Asphalt Paving   11-01-2020  PDF |  ZIP  CCR
UFGS 33 16 15 Water Storage Steel Tanks   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 16.16 Steel H-Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 32 12 17.19 Fuel Resistant Asphalt Paving For Airfields - Surface Course   11-01-2020  PDF |  ZIP  CCR
UFGS 01 50 00 Temporary Construction Facilities and Controls   11-01-2020  PDF |  ZIP  CCR
UFGS 31 62 19 Timber Piles   11-01-2020  PDF |  ZIP  CCR
UFGS 32 12 36.26 Polymer Concrete Micro-Overlay (PCMO) For Fuel And Abrasion Resistant Wearing Surfaces   11-01-2020  PDF |  ZIP  CCR
UFGS 01 45 35 Special Inspections   11-01-2020  PDF |  ZIP  CCR
UFGS 13 49 10 X-Ray Shielding   11-01-2020  PDF |  ZIP  CCR
UFGS 32 13 13.17 Roller Compacted Concrete Paving   11-01-2020  PDF |  ZIP  CCR
UFGS 35 45 04.00 10 Submersible Pump, Centrifugal Type   11-01-2020  PDF |  ZIP  CCR
UFGS 01 20 00 Price and Payment Procedures   11-01-2020  PDF |  ZIP  CCR
UFGS 27 52 24 Nurse Call System   11-01-2020  PDF |  ZIP  CCR
UFGS 26 55 80 Surgical, Procedure and Exam Lighting Fixtures   11-01-2020  PDF |  ZIP  CCR
UFGS 23 81 23 Computer Room Air Conditioning Units   11-01-2020  PDF |  ZIP  CCR
UFGS 31 32 19.13 Geogrid Soil Stabilization   02-01-2021  PDF |  ZIP  CCR
UFGS 31 35 19.13 Geogrid Slope Protection   02-01-2021  PDF |  ZIP  CCR
UFGS 09 67 23.15 Fuel Resistive Resinous Flooring, 3-Coat System   02-01-2021  PDF |  ZIP  CCR
UFGS 31 05 19.13 Geotextiles for Earthwork   02-01-2021  PDF |  ZIP  CCR
UFGS 09 67 23.16 Fuel Resistive Resinous Flooring, 5-Coat System   02-01-2021  PDF |  ZIP  CCR
UFGS 26 27 14.00 20 Electricity Metering   02-01-2021  PDF |  ZIP  CCR
UFGS 31 43 13.13 Concrete Pressure Grouting   02-01-2021  PDF |  ZIP  CCR
UFGS 09 90 00 Paints and Coatings   02-01-2021  PDF |  ZIP  CCR
UFGS 31 56 13.13 Soil-Bentonite Slurry Walls   02-01-2021  PDF |  ZIP  CCR
UFGS 31 10 00 Site Clearing   02-01-2021  PDF |  ZIP  CCR

Pages