Introduction
Within This Page
This Resource Page discusses the fundamentals and basics of the cost impact of implementing the security requirements of the Interagency Security Committee (ISC) Security Design Criteria. The General Services Administration (GSA) and the federal government are committed to excellence in the design and development of their sites and buildings. This requires an integrated approach that achieves the highest quality of aesthetics in meeting client and building requirements, while delivering a building that is cost-effective to maintain throughout its useful life. One challenge to the GSA and other federal agencies is to explore the extent to which maintaining high quality in design and construction has been affected by security. See WBDG Balancing Security/Safety and Sustainability Objectives. Specific GSA initiatives affecting capital construction include but are not limited to:
- Construction Excellence Program
- Raised Flooring Systems
- Sustainable Design
- Seismic Standards
- Security Measures
In this Resource Page, the costs associated with necessary security measures are discussed as they relate to standoff distance. Security issues considered herein are those required by application of the Interagency Security Committee (ISC) Security Design Criteria that applies to all new construction and major modernization of federal properties.
Description
Security-related costs arise from ISC requirements that influence the design of structural components and non-structural components. For example, the requirements for consideration of blast threats to the facility impact the design, and thus cost, of the structural frame and façade elements including walls, roof, and windows.
The impact of design explosive threat level on cost is reflected in the increased requirements of structural components, e.g., thicker walls, additional reinforcement, blast-resistant glazing and frames, etc. The two primary blast-related factors that influence the design of a structural component are the design threat magnitude (e.g., lbs TNT) and the distance between the potential explosion and the structural component, i.e., the standoff. Note that standoff is the distance to the structure from a defended perimeter, i.e., the closest distance to the design threat.
An increase in explosive weight or a decrease in standoff generally increases structural requirements. Since the ISC Security Criteria impose the design explosive weight magnitude for each level of protection, the building design is influenced by the amount of standoff available. For the defined threat level in the criteria for a particular facility, the designer must balance the effect of available standoff by incorporating blast-resistant design and/or hazard mitigation measures.
The effects of standoff on various structural and non-structural components are illustrated in Fig. 1. This figure generally illustrates, at no particular scale, the general trends and relationships between standoff and cost of protection. A number of the various components of incremental security cost are shown, including structural and non-structural component contributors.

Fig. 1. Impact of standoff distance on component costs. The relative magnitude and scale of these relationships vary from project to project.
Image Credit: GSA and Applied Research Associates
For example, the cost associated with hardening the mailroom, loading dock, and lobby to meet the ISC requirements is usually relatively small, and does not vary with the available standoff. The cost associated with progressive collapse considerations is also constant with standoff, since it is normally treated as threat-independent. There is a point at smaller standoffs where the framing design is further impacted by the blast loading on the frame, resulting in larger framing members and additional cost. This region is illustrated in the close-in regions, particularly within about 50 ft. As the standoff gets very small, costs increase dramatically.
The requirements for walls and windows are a function of standoff, as indicated for larger standoff. However, the ISC Security Criteria places limits on the maximum levels for which various components must be designed. The limits placed on the design blast pressure and impulse for the medium and higher levels of protection cap the cost at a particular standoff (limit) such that cost for walls and windows does not increase within this limit. It must be noted that this limitation in blast resistance in this region increases the inherent risk accepted with decreasing standoff.
The sum of the varying costs of hardening for the various components results in the "cost of hardening" curve indicated on Fig. 1. This function generally has a plateau between about 50 ft. standoff and the limit value for the relevant level of protection. At closer standoff, costs usually increase rapidly due to increased framing requirements. At larger standoff values, costs decrease to a plateau where conventional design requirements may govern.
One cost component that increases with increasing standoff is that for land (site area) and perimeter protection. For example, to provide increased standoff, the distance to the defended perimeter must increase, thereby increasing the area of the site and the length of the perimeter that must be protected.
Finally, adding the cost of hardening and the cost of land and perimeter protection results in the general function indicated as "Total Protection Cost". The characteristics of this function, with an increase at small standoff and increasing with larger standoff, indicate that a minimal cost may lie in a moderate range of standoff. At standoff values within the limit inherent in the blast design loads limits, the risk continues to increase with decreasing standoff. Nominal workable standoff values in the range of 20 ft. to 100 ft. are generally acceptable and achievable for GSA facilities. The risk and cost for standoff values less than 20 ft. generally are unacceptably high. Providing standoff values greater than 50 ft. can reduce risk further. A standoff distance of at least 50 ft. is generally preferred.
The figure and discussion above illustrate general characteristics of the cost and risk functions. Actual relative magnitudes and significance of individual cost components vary for each case considered, i.e., these relationships will be different for each building and site considered.
For information about physical security strategies, see WBDG Secure / Safe Branch, Designing Buildings to Resist Explosive Threats, and Retrofitting Existing Buildings to Resist Explosive Threats.
Application
The designs resulting from application of the Interagency Security Committee (ISC) Security Design Criteria offer protection from smaller explosive threats and reduce collateral damage effects from larger threats. The blast design criteria provided in the ISC Security Design Criteria, focusing on smaller threats, reflects numerous years of experience in blast effects and constraints on current designs. The experience and constraints include:
- Most fatalities in bombings result from collapse of the building.
- Many deaths and severe injuries occur due to wall and window debris.
- Progressive and/or widespread collapse should be avoided.
- It is important to have sustainable, attractive, and functional facilities.
- Some risk must be accepted if windows and other components are to be affordable and functional. See WBDG Threat/Vulnerability Assessments and Risk Analysis.
Recognition and application of these facts and constraints leads to the following principles for blast-resistant design:
- Take reasonable steps to prevent any collapse, if possible.
- Minimize the potential for progressive collapse, regardless of threats.
- Accept some additional risk by limiting design requirements for windows and walls.
These principles are reflected in the ISC Security Design Criteria and in the security-related costs related to its implementation. Structural component costs affected by the implementation of the blast resistance provisions of the ISC Security Criteria include:
- Roof
- Exterior walls
- Exterior windows
- Structural frame
- Special areas
In addition to typical exterior windows, glazing affected by security considerations includes skylights, curtain walls, and ballistic-glazed windows. For information on mitigating glazing hazards, see WBDG Glazing Hazard Mitigation. Hardening of special areas such as underground parking levels beneath the building and loading docks and mailrooms add to security cost. Site-related security costs include vehicle barriers, perimeter barriers, and added site lighting. For additional information about site-related security see WBDG resource pages Effective Site Security Design, Site Security Design Process and Landscape Architecture and the Site Security Design Process.
The costs for all of the above-mentioned items must be accounted for in developing cost estimates. Further, designers may need to quantify other costs related to security requirements including, but not limited to:
- Added signage
- Site-related security measures—access driveway reconfiguration, barriers, bollards, loading docks, prevailing winds, protection of site utilities and infrastructure
- Landscape design for security—topographic and/or vegetative visual control, physical and/or vegetative barriers
- Strengthened interior doors
- HVAC—raised air intakes
- HVAC—redundancy of utilities
- HVAC—protection of ventilation equipment
- Emergency power protection
- Telephone service redundancy
- Separate/redundant water supply pumps
- Backup control center
- Security key system
- Emergency duress stations
- Other cost items.
Relevant Codes and Standards
Mandates
- Executive Order 12977, "Interagency Security Committee"
- Interagency Security Committee Policies, Standards, and Best Practices—ISC standards and best practices can be used to help federal security professionals implement security policies and mandatory standards.
- The Risk Management Process: An Interagency Security Committee Standard
- The Risk Management Process for Federal Facilities, Appendix A: Design-Basis Threat Report (FOUO)
- UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings—Establishes prescriptive procedures for threat, vulnerability, and risk assessments and security design criteria for DoD facilities (official use only; Public versions available)
Federal Guidelines
- Department of Defense
- DOD Anti-Terrorism Construction Standards (official use only)
- FM 3-19.30 Physical Security—Sets forth guidance for all personnel responsible for physical security
- UFC 1-200-01 DoD Building Code (General Building Requirements)
- UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings
- Department of State
- Architectural Engineering Design Guideline (5 Volumes) (limited official use only)
- Physical Security Standards Handbook, 07 January 1998. (limited official use only)
- Structural Engineering Guidelines for New Embassy Office Buildings, August 1995. (limited official use only)
- General Services Administration (GSA)
- PBS-P100 Facilities Standards for the Public Buildings Service—Chapter 8
- Other "official use only" documents may be obtained from the Office of Design and Construction.
Additional Resources
Security Criteria Centers
- Defense Threat Reduction Agency—Department of Defense (DOD) Anti-terrorism body—Pentagon's J34
- Department of Homeland Security Federal Protective Service
- Naval Facilities Engineering Command (NAVFAC), Engineering and Expeditionary Warfare Center
- U.S. Army Corps of Engineers, Protective Design Center
- U.S. Department of Defense
Publications
- Anti-Terrorism: Criteria, Tools & Technology by Joseph L. Smith, Applied Research Associates, Inc. 2003.
- Architectural Design for Security and Security and Technology Design by Donald M. Rochon. June 1998.
- Building Security: Handbook For Architectural Planning And Design by Barbara A. Nadel, FAIA, Editor-in-Chief, 2004.
- Designing for Crime and Terrorism, Security and Technology Design by Randall I. Atlas. June 1998.