Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Jan-2008 | A | UFGS 11 46 00 Food Dispensing Equipment | Jan-2008 | N | Superseding UFGS 11 40 00.00 20 Food Service Equipment and UFGS 11 46 01.00 10 Food Service Equipment | |
Jan-2008 | A | UFGS 11 46 01.00 10 Food Service Equipment | Oct-2007 | D | Superseded by the following UFGS sections: 11 05 40 Common Work Results for Foodservice Equipment, 11 06 40.13 Foodservice Equipment Schedule, 11 41 11 Refrigerated and Frozen Food Storage Equipment, 11 42 00 Food Preparation Equipment, 11 44 00 Food Cooking Equipment, 11 46 00 Food Dispensing Equipment, 11 48 00 Cleaning and Disposal Equipment, and 12 35 20 Foodservice Casework, Countertops, and Accessories Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 11 47 00 Ice Machines | Jan-2008 | N | New section | |
Jan-2008 | N | UFGS 11 48 00 Cleaning and Disposal Equipment | Jan-2008 | N | Superseding UFGS 11 40 00.00 20 Food Service Equipment and UFGS 11 46 01.00 10 Food Service Equipment | |
Jan-2008 | S | UFGS 12 30 00.00 40 Casework | Apr-2007 | D | Superseded by UFGS 12 31 00 Manufactured Metal Casework, UFGS 12 32 00 Manufactured Wood Casework, UFGS 12 34 00 Manufactured Plastic Casework,and UFGS 12 36 00 Countertops Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 12 31 00 Manufactured Metal Casework | Jan-2008 | N | Superseding UFGS 12 30 00.00 40 Casework, UFGS 12 35 30.00 10 Residential Cabinets and Countertops, and UFGS 12 35 30.00 20 Residential Casework | |
Jan-2008 | S | UFGS 12 32 00 Manufactured Wood Casework | Jan-2008 | N | Superseding UFGS 12 30 00.00 40 Casework, UFGS 12 35 30.00 10 Residential Cabinets and Countertops, and UFGS 12 35 30.00 20 Residential Casework | |
Jan-2008 | S | UFGS 12 34 00 Manufactured Plastic Casework | Jan-2008 | N | Superseding UFGS 12 30 00.00 40 Casework, UFGS 12 35 30.00 10 Residential Cabinets and Countertops, and UFGS 12 35 30.00 20 Residential Casework | |
Jan-2008 | A | UFGS 12 35 20 Foodservice Casework, Countertops, and Accessories | Jan-2008 | N | Superseding UFGS 11 40 00.00 20 Food Service Equipment and UFGS 11 46 01.00 10 Food Service Equipment | |
Jan-2008 | A | UFGS 12 35 30.00 10 Residential Cabinets and Countertops | Apr-2006 | D | Superseded by UFGS 12 31 00 Manufactured Metal Casework, UFGS 12 32 00 Manufactured Wood Casework, UFGS 12 34 00 Manufactured Plastic Casework,and UFGS 12 36 00 Countertops Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | N | UFGS 12 35 30.00 20 | Apr-2006 | D | Superseded by UFGS 12 31 00 Manufactured Metal Casework, UFGS 12 32 00 Manufactured Wood Casework, UFGS 12 34 00 Manufactured Plastic Casework,and UFGS 12 36 00 Countertops Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 12 36 00 Countertops | Jan-2008 | N | Superseding UFGS 12 30 00.00 40 Casework, UFGS 12 35 30.00 10 Residential Cabinets and Countertops, and UFGS 12 35 30.00 20 Residential Casework | |
Jan-2008 | S | UFGS 13 34 00.00 40 Fabricated Engineered Structures | Jul-2007 | D | Superseded by UFGS 13 34 19 Metal Building Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | N | UFGS 13 34 19 Metal Building Systems | Jan-2008 | R | Titled changed from Preengineered Metal Buildings; Added USACE and NASA requirements. Superseding UFGS 13 34 00.00 40 Fabricated Engineered Structures, and UFGS 13 34 20 Metal Building Systems (Minor Requirements) | |
Jan-2008 | A | UFGS 13 34 20 Metal Building Systems (Minor Requirements) | Oct-2007 | D | Superseded by UFGS 13 34 19 Metal Building Systems Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 13 50 00.00 40 Special Instrumentation | Apr-2007 | D | Retired; Section is redundant Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 21 30 00 Fire Pumps | Jan-2008 | R | revised reference: NEMA MG1 Motor | |
Jan-2008 | A | UFGS 22 04 00.00 10 Plumbing, Hospital | Jan-2008 | R | Revised Table III | |
Jan-2008 | S | UFGS 22 15 09 General Service Compressed-Air Systems Cleaning Procedures | Jan-2008 | R | Switched Section Number and Title with Section 22 15 14.00 40 | |
Jan-2008 | S | UFGS 22 15 14.00 40 General Service Compressed-Air Systems, Low Pressure | Jan-2008 | R | Switched Section Number and Title with Section 22 15 09 | |
Jan-2008 | A | UFGS 22 33 30.00 10 Solar Water Heating Equipment | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 07 00 Thermal Insulation for Mechanical Systems | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 08 00.00 10 Commissioning of HVAC Systems | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 10 00 Fuel Storage Systems | Oct-2007 | D | Superseded by UFGS 33 56 10 Factory-Fabricated Fuel Storage Tanks Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 23 52 00.00 10 Water and Steam Heating; Oil, Gas or Both; Up to 20 MBTUH | Jan-2008 | R | In response to CCR 1579 | |
Jan-2008 | A | UFGS 23 52 43.00 10 Heat Recovery Boilers | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 54 16.00 10 Heating System; Gas-Fired Heaters | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 57 10.00 10 Forced Hot Water Heating Systems Using Water and Steam Heat Exchangers | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 64 00.00 10 Liquid Chillers | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 65 00.00 10 Cooling Tower | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 70 01.00 10 Central Steam-Generating System, Coal-Fired | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 70 02.00 10 Central Steam Generating System - Combination Gas and Oil Fired | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 70 03.00 10 Heating and Utilities Systems, Central Steam | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 71 19 Thermal Energy Storage System: Ice-On-Coil | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 72 00 Energy Recovery Systems | Jan-2008 | R | Incorporated EPAct05 requirements [23 72 00.00 10] | |
Jan-2008 | A | UFGS 23 72 26.00 10 Desiccant Cooling Systems | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 76 00.00 10 Evaporative Cooling Systems | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 82 01.00 10 Warm Air Heating Systems | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 23 82 02.00 10 Unitary Heating and Cooling Equipment | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | S | UFGS 26 05 73.00 40 Overcurrent Protective Devices | Jan-2008 | R | Updated Criteria | |
Jan-2008 | N | UFGS 26 33 53.00 20 Uninterruptible Power Supply (UPS) | Jan-2008 | R | Revised paragraphs 3.1 and 3.3.1 | |
Jan-2008 | N | UFGS 26 42 22.00 20 Cathodic Protection System for Steel Water Tanks | Jan-2008 | R | Titled changed from Cathodic Protection System (Steel Water Tanks); Extensive revisions; First step in unification of agency sections. | |
Jan-2008 | N | UFGS 27 10 00 Building Telecommunications Cabling System | Jan-2008 | R | Added hyperlink to Army ECB 2007-22 in notes. | |
Jan-2008 | S | UFGS 28 05 26 Grounding and Bonding for Electronic Safety and Security | Jan-2008 | N | Superseding UFGS 28 05 26.00 40 with no title change | |
Jan-2008 | S | UFGS 28 05 26.00 40 Grounding and Bonding for Electrical Systems | Jul-2007 | D | Renumbered; Superseded by UFGS 28 05 26 with same title Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 31 62 16.00 10 Steel H-Piles | Oct-2007 | D | Superseded by UFGS 31 62 16.16 Steel H-Piles Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | N | UFGS 31 62 16.16 Steel H-Piles | Jan-2008 | R | Added USACE requirements | |
Jan-2008 | N | UFGS 31 62 19 Timber Piles | Jan-2008 | N | Superseding UFGS 31 62 19.00 20 Timber Piles; Added USACE requirements | |
Jan-2008 | N | UFGS 31 62 19.00 20 Timber Piles | Apr-2006 | D | Superseded by UFGS 31 62 19 Timber Piles Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 31 62 20.00 10 Round Timber Piles | Oct-2007 | D | Superseded by UFGS 31 62 19 Timber Piles Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 32 01 28 Partial-Depth Patching of Rigid Pavements | Jan-2008 | R | Includes Epoxy-Resin Requirements; Old Section Title: Patching of Rigid Pavements | |
Jan-2008 | A | UFGS 32 31 00.00 10 Fencing | Apr-2006 | D | Superseded by UFGS 32 31 13 Chain Link Fences and Gates, UFGS 32 31 13.53 High-Security Chain Link Fences and Gates, and UFGS 32 31 26 Wire Fences and Gates Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 32 31 13 Chain Link Fences and Gates | Jan-2008 | N | Superseding UFGS 32 31 00.00 10 Fencing, UFGS 32 31 13.00 20 Chain Link Fences and Gates, and UFGS 32 31 13.00 40 Chain Link Fences and Gates | |
Jan-2008 | N | UFGS 32 31 13.00 20 Chain Link Fences and Gates | Jul-2006 | D | Superseded by UFGS 32 31 13 Chain Link Fences and Gates and UFGS 32 31 13.53 High-Security Chain Link Fences and Gates Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 32 31 13.00 40 Chain Link Fences and Gates | Jul-2007 | D | Superseded by UFGS 32 31 13 Chain Link Fences and Gates and UFGS 32 31 13.53 High-Security Chain Link Fences and Gates Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 32 31 13.53 High-Security Fences (Chain Link and Ornamental) and Gates | Jan-2008 | N | Superseding UFGS 32 31 00.00 10 Fencing, UFGS 32 31 13.00 20 Chain Link Fences and Gates, and UFGS 32 31 13.00 40 Chain Link Fences and Gates | |
Jan-2008 | A | UFGS 32 31 26 Wire Fences and Gates | Jan-2008 | N | Superseding UFGS 32 3100.00 10 Fencing | |
Jan-2008 | S | UFGS 33 32 13.13 40 Packaged Sewage Lift Stations, Wet Well Type | Jul-2007 | D | Section renumbered to 33 32 13.13 with no title change Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | S | UFGS 33 32 13.13 Packaged Sewage Lift Stations, Wet Well Type | Jan-2008 | N | Section renumbered/superseding UFGS 33 32 13.13 40 with no title change | |
Jan-2008 | N | UFGS 33 32 13.14 Packaged Sewage Lift Stations, Grinder Pump Type | Jan-2008 | N | New section superseding, in part, UFGS 33 32 16.13 Package [Grinder Pump] [Lift] Station | |
Jan-2008 | N | UFGS 33 32 16.13 Package [Grinder Pump] [Lift] Station | Apr-2006 | D | Superseded by UFGS 33 32 13.13 Packaged Sewage Lift Stations, Grinder Pump Type Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 33 40 00 Stormwater Utilities | Jan-2008 | N | Superseding UFGS 33 40 01 Storm Drainage and UFGS 33 40 00.00 40 Storm Drainage Utilities | |
Jan-2008 | S | UFGS 33 40 00.00 40 Storm Drainage Utilities | Apr-2007 | D | Renumbered/Superseded by UFGS 33 40 00 Storm Drainage Utilities Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 33 40 01 Storm Drainage | Jul-2006 | D | Renamed UFGS 33 40 00 Storm Drainage Utilities Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 33 56 10 Factory-Fabricated Fuel Storage Tanks | Jan-2008 | N | Superseding UFGS 23 10 00 Fuel Storage Systems and UFGS 33 56 13 Aboveground Fuel Oil Storage Tanks, and UFGS 33 56 16 Underground Petroleum Tanks | |
Jan-2008 | N | UFGS 33 56 13 Aboveground Fuel Oil Storage Tanks | Apr-2006 | D | Superseded by UFGS 33 56 10 Factory-Fabricated Fuel Storage Tanks Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | N | UFGS 33 56 16 Underground Petroleum Tanks | Apr-2006 | D | Superseded by UFGS 33 56 10 Factory-Fabricated Fuel Storage Tanks Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Jan-2008 | A | UFGS 33 60 00.00 10 Central High Temperature Water (HTW) Generating Plant and Auxiliaries | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 35 20 16.33 Hydraulic Miter Gates | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 20 16.39 Hydraulic Sector Gates | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 20 16.46 Hydraulic Tainter Gates and Anchorages | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 20 16.53 Hydraulic Vertical Lift Gates | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 20 16.59 Closure Gates | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 20 20 Electrical Equipment for Gate Hoist | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 31 19 Stone, Channel, Shoreline/Coastal Protection for Structures | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 31 19.20 Articulating Concrete Block Revetments | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 41 00 Levee Construction | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 35 42 34 Reinforced Soil Slope | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | N | UFGS 35 59 13.16 Extruded and Molded Marine Fenders | Jan-2008 | R | Changes made to paras 1.3, 1.4.2g, 2.2.7, 2.3.1, 2.3.4.1, 2.3.4.2, 2.3.6 | |
Jan-2008 | A | UFGS 35 73 13 Embankment for Earth and Rockfill Dams | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 41 22 15.00 10 Overhead Electric Cranes | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 41 22 23.19 10 Monorails with Electric, Air, or Manual Powered Hoist | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 41 24 26 Hydraulic Power Systems | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 41 24 27.00 10 Hydraulic Power Systems for Civil Works Structures | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 41 36 30.00 10 Ultrasonic Inspection of Plates | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 41 65 10.00 10 [Diesel] [Natural Gas] Fueled Engine Pump Drives | Jan-2008 | R | Compliance with CSI SectionFormat | |
Jan-2008 | A | UFGS 43 11 00 Fans/Blowers/Pumps; Off-Gas | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 43 21 13 Pumps: Water, Centrifugal | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 43 21 39 Pumps: Water, Vertical Turbine | Jan-2008 | R | Incorporated EPAct05 requirements | |
Jan-2008 | A | UFGS 43 32 76 Chlorine-Feeding Machines (Automatic, Semiautomatic and Manual) | Jan-2008 | R | Compliance with CSI SectionFormat | |
Oct-2007 | N | UFGS 00 73 03 Supplementary Conditions for Azores Projects | Oct-2007 | R | Renumbered paragraphs | |
Oct-2007 | S | UFGS 01 31 19.00 40 | Apr-2006 | D | Redundant, section deleted. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | N | UFGS 01 35 29 Safety and Occupational Health Requirements | Oct-2007 | R | Corrected organization in reference article | |
Oct-2007 | A | UFGS 01 45 35 Special Inspections | Oct-2007 | R | Updated seismic criteria | |
Oct-2007 | A | UFGS 01 50 00 Temporary Construction Facilities and Controls | Oct-2007 | N | Superseding UFGS 01 50 00.00 20 Temporary Facilities and Controls, UFGS 01 50 00.00 40 Temporary Facilities and Controls, and UFGS 01 50 02.00 10 Temporary Construction Facilities | |
Oct-2007 | N | UFGS 01 50 00.00 20 Temporary Facilities and Controls | Apr-2006 | D | Superseded by UFGS 01 50 00 Temporary Construction Facilities and Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | S | UFGS 01 50 00.00 40 Temporary Facilities and Controls | Apr-2006 | D | Superseded by UFGS 01 50 00 Temporary Construction Facilities and Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | A | UFGS 01 50 02.00 10 Temporary Construction Facilities | Apr-2006 | D | Superseded by UFGS 01 50 00 Temporary Construction Facilities and Controls. Note: The last published PDF version of this Section is available in the previous release in the UFGS Archives. | |
Oct-2007 | A | UFGS 02 51 13 Precipitation/Coagulation/Flocculation Water Treatment | Oct-2007 | R | Updated seismic criteria |