UFGS Changes and Revisions  Subscribe to UFGS Changes and Revisions

Related Materials: Policy on UFGS Changes and Revisions

Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.

To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.

To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.

After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.

To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.

KEY PREPARING ACTIVITY (PA) A Army N Navy F Air Force S NASA
ACTION N New R Revision C Change D Deletion
Release PA UFGS Section Actionsort descending Change # Nature of Change or Revision
Oct-2007 A UFGS 43 31 13.14 Downflow Liquid Activated Carbon Adsorption Units R Updated seismic criteria
Oct-2007 A UFGS 44 10 00 Air Pollution Control R Updated seismic criteria
Oct-2007 A UFGS 44 11 33 Thermal (Catalytic) Oxidation Systems R Updated seismic criteria
Oct-2007 A UFGS 44 41 13 Prefabricated Biochemical Wastewater Treatment Plant R Updated seismic criteria
Oct-2007 A UFGS 44 43 00 Filtration System R Updated seismic criteria
Oct-2007 A UFGS 44 44 53 Advanced Oxidation Processes (AOP) R Updated seismic criteria
Oct-2007 A UFGS 44 46 19 Sludge-Digester Gas, Heating, and Mixing System R Updated seismic criteria
Jul-2007 N UFGS 01 11 00 Summary of Work R Corrected hyperlink to CCB.
Jul-2007 N UFGS 01 14 00 Work Restrictions R Added paragraph on smoking policy.
Jul-2007 A UFGS 01 32 01.00 10 Project Schedule R Revised in response to CCRs 1117 and 1120; submittal paragraph added
Jul-2007 S UFGS 01 35 23.00 40 Owner Safety Requirements R Reference Update
Jul-2007 N UFGS 01 45 01.00 20 Quality Control (QC) - Minor Construction R Modified requirements for submitting reports on contracts and task orders less than $750K
Jul-2007 S UFGS 03 30 00.00 40 Cast-in-Place Concrete R Reference and Section References (SRF) update
Jul-2007 S UFGS 03 30 53.00 40 Miscellaneous Cast-in-Place Concrete R Reference Update
Jul-2007 S UFGS 03 41 33.00 40 Precast Structural Pretensioned Concrete R Reference and Section References (SRF) update
Jul-2007 S UFGS 03 45 00.00 40 Precast Architectural Concrete R Reference Update
Jul-2007 S UFGS 03 47 00.00 40 Site-Cast Concrete R Section References (SRF) update
Jul-2007 S UFGS 03 50 00.00 40 Cast Decks and Underlayments R Reference Update
Jul-2007 S UFGS 05 14 00.13 Welding Structural Aluminum Framing R Reference Update
Jul-2007 S UFGS 05 51 00.00 40 Metal Stairs R Reference and Section References (SRF) update
Jul-2007 S UFGS 06 18 00 Glued-Laminated Construction R Reference Update
Jul-2007 S UFGS 07 40 00.00 40 Roofing and Siding Panels R Reference Update
Jul-2007 S UFGS 07 46 19.00 40 Steel Siding R Reference Update
Jul-2007 S UFGS 08 13 73.00 40 Sliding Metal Doors R Reference Update
Jul-2007 S UFGS 08 44 00.00 40 Curtain Wall and Glazed Assemblies R Reference and Section References (SRF) update
Jul-2007 S UFGS 09 23 82.00 40 Fireproof Gypsum Plastering R Reference Update
Jul-2007 S UFGS 09 96 00 High-Performance Coatings R Reference Update
Jul-2007 S UFGS 09 97 13.00 40 Steel Coatings R Reference Update
Jul-2007 N UFGS 10 51 13 Metal Lockers R Titled changed from Steel Clothing Lockers and unified with (NASA-prepared) UFGS 10 51 00.00 40 Lockers
Jul-2007 S UFGS 12 48 13.13 Entrance Floor Mats R Minor Text Change
Jul-2007 S UFGS 13 34 00.00 40 Fabricated Engineered Structures R Minor Text Change
Jul-2007 S UFGS 21 13 00.00 40 Fire-Suppression Sprinkler Systems R Reference Update
Jul-2007 S UFGS 21 13 26.00 40 Deluge Fire-Suppression Sprinkler Systems R Reference Update
Jul-2007 S UFGS 22 07 19.00 40 Plumbing Piping Insulation R Reference Update
Jul-2007 A UFGS 22 10 00.00 10 Vertical Pumps, Axial-Flow and Mixed-Flow Impeller-Type R Added ASTM F1476 requirement
Jul-2007 A UFGS 22 11 23.00 10 Submersible Pump, Axial-Flow and Mixed-Flow Type R Added ASTM F1476 requirement
Jul-2007 S UFGS 22 15 09 General Service Compressed-Air Systems Cleaning Procedures R Reference Update
Jul-2007 S UFGS 22 15 13.16 40 High-Pressure Compressed-Air Piping and Valves, Stainless R Reference Update
Jul-2007 S UFGS 22 15 14.00 40 General Service Compressed-Air Systems, High Pressure R Reference Update
Jul-2007 A UFGS 23 00 00 Air Supply, Distribution, Ventilation, and Exhaust Systems R Revised seal class A ductwork, registers, outdoor units, filters
Jul-2007 S UFGS 23 00 00.00 40 Heating, Ventilating, and Air Conditioning R Reference Update
Jul-2007 S UFGS 23 05 00.00 40 Common Work Results for HVAC R Reference Update
Jul-2007 S UFGS 23 07 13.00 40 Duct Insulation R Reference Update
Jul-2007 N UFGS 23 08 00.00 20 Commissioning of Mechanical[ and Plumbing] Systems R Added project drawing requirement in note
Jul-2007 S UFGS 23 09 33.00 40 Electric and Electronic Control System for HVAC R Reference Update
Jul-2007 S UFGS 23 09 33.13 40 Electric Control System for HVAC R Reference Update
Jul-2007 S UFGS 23 11 23.00 40 Facility Natural-Gas Piping R Reference Update
Jul-2007 N UFGS 23 21 13.23 20 [High] [Medium] Temperature Water System Within Buildings R Modified for non-asbestos use.
Jul-2007 S UFGS 23 22 13.13 40 Steam and Condensate Heating Piping R Reference Update
Jul-2007 S UFGS 23 31 11.11 40 Ducts, Low Pressure R Reference Update
Jul-2007 S UFGS 23 31 11.12 40 Ducts, Medium/High Pressure R Reference Update
Jul-2007 S UFGS 23 31 13.20 40 Welding Metal Ductwork R Reference and Section References (SRF) update
Jul-2007 S UFGS 23 34 23.00 40 HVAC Power Ventilators R Reference Update
Jul-2007 S UFGS 23 36 00 Air Terminal Units R Reference Update
Jul-2007 S UFGS 23 37 23.00 40 HVAC Gravity Ventilators R Reference Update
Jul-2007 S UFGS 23 41 13.00 40 Panel Filters R Reference Update
Jul-2007 N UFGS 23 52 33.01 20 Steam Heating Plant Watertube (Shop Assembled) Coal/Oil or Coal R Modified for non-asbestos use.
Jul-2007 N UFGS 23 52 33.02 20 Steam Heating Plant Watertube (Field Erected) Coal/Oil or Coal R Modified for non-asbestos use.
Jul-2007 N UFGS 23 52 33.03 20 Water-Tube Boilers, Oil/Gas or Oil R Modified for non-asbestos use.
Jul-2007 A UFGS 23 71 19 Thermal Energy Storage System: Ice-On-Coil R Div 05 Section References (SRF) changes
Jul-2007 S UFGS 23 73 13.00 40 Modular Indoor Central-Station Air-Handling Units R Section References (SRF) update
Jul-2007 S UFGS 23 81 43.00 40 Air-Source Unitary Heat Pumps R Section References (SRF) update
Jul-2007 S UFGS 23 82 16.00 40 Air Coils R Reference Update
Jul-2007 S UFGS 23 82 19.00 40 Fan Coil Units R Reference Update
Jul-2007 S UFGS 23 82 23.00 40 Unit Ventilators R Reference Update
Jul-2007 S UFGS 26 05 13.00 10 Medium-Voltage Cables R Reference Update
Jul-2007 S UFGS 26 05 73.00 40 Overcurrent Protective Devices R Title changed from Overcurrent Protective Devices Coordination Study; Reference Update
Jul-2007 S UFGS 26 09 23.00 40 Lighting Control Devices R Reference Update
Jul-2007 S UFGS 26 12 00.00 40 Medium-Voltage Transformers R Reference Update
Jul-2007 S UFGS 26 18 23.00 40 Medium-Voltage Surge Arresters R Reference Update
Jul-2007 N UFGS 26 20 00 Interior Distribution System R Section References (SRF) update
Jul-2007 S UFGS 26 24 16.00 40 Panelboards R Reference and Section References (SRF) update
Jul-2007 S UFGS 26 24 19.00 40 Motor-Control Centers R Reference and Section References (SRF) update
Jul-2007 S UFGS 26 27 26.00 40 Wiring Devices R Reference Update
Jul-2007 S UFGS 26 28 16.00 40 Enclosed Switches and Circuit Breakers R Section References (SRF) update
Jul-2007 S UFGS 26 35 33.00 40 Power Factor Correction Equipment R Reference and Section References (SRF) update
Jul-2007 S UFGS 26 41 00.00 40 Lightning Protection System R Reference Update
Jul-2007 N UFGS 26 51 00 Interior Lighting R Corrected link in paragraph "Occupancy Sensor" (3.1.7).
Jul-2007 S UFGS 26 51 13.08 40 Incandescent Lighting R Reference Update
Jul-2007 S UFGS 26 52 00.00 40 Emergency Lighting R Reference Update
Jul-2007 S UFGS 26 54 00.00 40 Classified, Special Purpose, Exterior Lighting R Reference Update
Jul-2007 S UFGS 26 56 36.00 40 Flood Lighting R Reference Update
Jul-2007 S UFGS 26 60 13 Low-Voltage Motors R Title changed from Medium-Voltage Controllers; Superseding UFGS 26 18 39.00 40 Medium-Voltage Controllers
Jul-2007 S UFGS 27 05 28.36 40 Cable Trays for Communications Systems R Reference Update
Jul-2007 N UFGS 27 10 00 Building Telecommunications Cabling System R Corrected MF95 section references in notes
Jul-2007 S UFGS 28 05 26.00 40 Grounding and Bonding for Electrical Systems R Reference and Section References (SRF) update
Jul-2007 S UFGS 28 31 53.00 40 Fire Alarm Initiating Devices R Reference Update
Jul-2007 S UFGS 28 33 00.00 40 Fuel-Gas Detection and Alarm R Reference Update, Renamed Reference Organization
Jul-2007 A UFGS 31 36 00 Gabions R reformatted DEFINITIONS
Jul-2007 A UFGS 32 13 11 Concrete Pavement for Airfields and Other Heavy-Duty Pavements R Revision for diamond grinding and supplemental cements, silica and admixtures
Jul-2007 A UFGS 32 13 16.16 Roller Compacted Concrete (RCC) Pavement R Complete revision; added appendices
Jul-2007 S UFGS 32 31 13.00 40 Chain Link Fences and Gates R Reference Update
Jul-2007 S UFGS 33 32 13.13 40 Packaged Sewage Lift Stations, Wet Well Type R Section References (SRF) update
Jul-2007 S UFGS 33 73 00.00 40 Utility Transformers R Section References (SRF) update
Jul-2007 S UFGS 33 75 00.00 40 Switchgear and Protection Devices R Section References (SRF) update
Jul-2007 S UFGS 33 77 19.00 40 Medium-Voltage Switch R Reference and Section References (SRF) update
Jul-2007 S UFGS 40 18 00.00 40 Vacuum Systems Process Piping R Reference Update
Jul-2007 S UFGS 40 95 33.23 40 Fiber Optic Process Control Networks R Reference Update
Jul-2007 S UFGS 42 22 00.00 40 Process Chillers and Coolers R Reference and Section References (SRF) update
Jul-2007 S UFGS 42 22 16.00 40 Reciprocating Process Chillers and Coolers R Section References (SRF) update