Related Materials: Policy on UFGS Changes and Revisions
Below is a listing of the Revisions and Changes made to UFGS Sections for each quarterly release.
To view a list for a specific UFGS Release, select the UFGS release date from the 'Release' drop-down and click 'Apply'.
To view a list of all the revisions and changes made to a specific UFGS Section, select 'Any' from the "Release' drop down, type the Section number into the Search bar and select the Section to view, then click 'Apply'.
After clicking 'Apply', you can PRINT REPORT, which will include the nature of the change/revision.
To view the complete detailed history of all the revisions and changes made to a UFGS Section, click on the Section title.
KEY | PREPARING ACTIVITY (PA) | A Army | N Navy | F Air Force | S NASA |
---|---|---|---|---|---|
ACTION | N New | R Revision | C Change | D Deletion |
Release | PA | UFGS Section | Date | Action | Change # | Nature of Change or Revision |
---|---|---|---|---|---|---|
Nov-2008 | A | UFGS 31 60 00 Foundation Preparation | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 31 62 21 Piling: Composite, Wood and Cast In-Place Concrete | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 31 62 23.13 Concrete-Filled Steel Piles | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 31 63 16 Augered Cast-In-Place Piles | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 31 68 13 Soil and Rock Anchors | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 31 73 00 Tunnel and Shaft Grouting | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 32 12 11 Bituminous Surface Treatment | Nov-2008 | R | Corrected table units | |
Nov-2008 | A | UFGS 32 13 16.16 Roller Compacted Concrete (RCC) Pavement | Nov-2008 | R | Compliance with CSI SectionFormat | |
Nov-2008 | A | UFGS 33 70 02.00 10 Electrical Distribution System, Underground | Nov-2008 | R | Revision closing CCR 917 | |
Nov-2008 | S | UFGS 33 73 00.00 40 Utility Transformers | Nov-2008 | R | Revised throughout towards unification | |
Nov-2008 | S | UFGS 33 75 00.00 40 Switchgear and Protection Devices | Nov-2008 | R | Revised throughout towards unification | |
Nov-2008 | S | UFGS 33 77 19.00 40 Medium-Voltage Switch | Nov-2008 | R | Revised throughout towards unification | |
Nov-2008 | S | UFGS 33 77 36.00 40 Medium-Voltage Utility Fuses | Nov-2008 | R | Revised throughout towards unification | |
Nov-2016 | A | UFGS 01 45 00.00 10 Quality Control | Nov-2016 | R | Total review and update. | |
Nov-2016 | A | UFGS 02 83 19.13 10 Lead-Based Paint Abatement | Feb-2010 | R | Superseding UFGS 02 83 19.00 10 Lead Based Pain Hazard Abatement, Target Housing and Child Occupied Facilities; Nontechnical Number and Title Revision; Did not change Section date. | |
Nov-2016 | S | UFGS 03 41 33 Precast Structural Pretensioned Concrete | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | N | UFGS 06 13 33 Pier Timberwork | Nov-2016 | R | Revised to address changes in preservative treatments for Pier Timberwork. | |
Nov-2016 | S | UFGS 07 41 63 Fabricated Roof Panel Assemblies | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | S | UFGS 08 41 13 Aluminum-Framed Entrances and Storefronts | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | A | UFGS 09 06 00 Schedules for Finishes | May-2009 | R | Superseding UFGS 09 06 90 Schedules for Painting and Coating; Nontechnical Number and Title Revision; Did not change Section date. | |
Nov-2016 | S | UFGS 12 32 00 Manufactured Wood Casework | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | S | UFGS 21 21 00.00 40 Carbon-Dioxide Fire Extinguishing Systems | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | S | UFGS 22 05 83.63 Cured-In-Place Pipe (CIPP) Lining for Plumbing Applications | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | S | UFGS 22 15 09.00 40 General Service Compressed-Air Systems Cleaning Procedures | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | N | UFGS 23 64 00 Packaged Water Chillers, Absorption Type | Nov-2016 | R | Complete revision. | |
Nov-2016 | N | UFGS 23 64 10 Water Chillers, Vapor Compression Type | Nov-2016 | R | Complete revision. | |
Nov-2016 | N | UFGS 23 65 00 Cooling Towers and Remote Evaporatively-Cooled Condensers | Nov-2016 | R | Title changed from Cooling Towers; Complete review and update concerning cooling towers and remote evaporatively cooled condensers. | |
Nov-2016 | S | UFGS 26 05 13.00 10 Medium-Voltage Cables | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2016 | N | UFGS 31 62 19.13 Timber Marine Piles | Nov-2016 | R | Title changed from Wood Marine Piles; Revised to address changes in preservative treatments and basis of bids for Timber Marine Piles. | |
Nov-2016 | S | UFGS 32 31 13 Chain Link Fences and Gates | Nov-2016 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2011 | N | UFGS 01 14 00 Work Restrictions | Nov-2011 | R | Deleted subpart 1.5.18: "Commonwealth of Puerto Rico"; modified subparts 1.5.7 and 1.5.9 | |
Nov-2011 | N | UFGS 01 30 00 Administrative Requirements | Nov-2011 | R | Modified note in subpart 1.6, deleted subpart 1.12 "Fair Labor Standards Act for Puerto Rico", modified note in subpart 1.14 | |
Nov-2011 | N | UFGS 01 35 13 Special Project Procedures | Nov-2011 | R | Deleted subpart 3.2.4 "Annual Pearl Harbor Hydrofest" | |
Nov-2011 | N | UFGS 01 45 00.00 20 Quality Control | Nov-2011 | R | Added note before Part 1; modified subpart 1.2, 1.4.1, 1.5.2.1, 1.6.1.1 ; removed subpart 1.16 | |
Aug-2015 | A | UFGS 10 11 00 Visual Display Units | Feb-2009 | R | Superseding UFGS 10 10 00 Visual Communications Specialties; Nontechnical number and title revision; Did not change Section date. | |
Aug-2015 | A | UFGS 10 14 00.10 Exterior Signage | Apr-2006 | R | Superseding UFGS 10 14 01 Exterior Signage; Nontechnical Section number revision; Did not change Section date. | |
Aug-2015 | A | UFGS 10 26 00 Wall and Door Protection | Aug-2010 | R | Superseding UFGS 10 26 13 Wall and Corner Guards ; Nontechnical number and title revision; Did not change Section date | |
Aug-2015 | A | UFGS 11 13 19.13 Loading Dock Levelers | Aug-2009 | R | Superseding UFGS 11 13 10 Dock Levelers; Nontechnical number and title revision; Did not change Section date. | |
Aug-2015 | S | UFGS 12 36 00 Countertops | Aug-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
Aug-2015 | A | UFGS 12 59 00 Systems Furniture | Feb-2009 | R | Superseding UFGS 12 50 00 Furniture Systems; Nontechnical number and title revision; Did not change Section date. | |
Aug-2015 | A | UFGS 12 61 13 Upholstered Audience Seating | Aug-2008 | R | Superseding UFGS 12 65 00 Fixed Seating; Nontechnical number and title revision; Did not change Section date. | |
Aug-2015 | A | UFGS 13 49 20.00 10 RFI/EMI Shielding | Oct-2007 | R | Superseding UFGS 13 27 54.00 10 Electromagnetic (EMI) Shielding; Nontechnical number and title revision; Did not change Section date. | |
Aug-2015 | S | UFGS 22 66 53.00 40 Laboratory Chemical-Waste and Vent Piping | Aug-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
Aug-2015 | S | UFGS 23 05 48.00 40 Vibration and Seismic Controls for HVAC Piping and Equipment | Aug-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
Aug-2015 | S | UFGS 23 22 23.00 40 Steam Condensate Pumps | Aug-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
Aug-2015 | N | UFGS 33 56 13.13 Steel Tanks With Fixed Roofs | Aug-2015 | R | UFGS has been revised throughout. Modifications included references, submittals, new jet fuels and requirements for the following in accordance with the update of DoD Aboveground Storage Tank Standard AW 78-24-27: columns, pressure/vacuum vents, antirotation cables, center roof vents, roof manholes, roof circulation vent/inspection hatches, water draw-off systems, sidestream filtration systems, weld inspections and stilling wells. | |
Aug-2015 | N | UFGS 33 56 13.15 Undertank Interstitial Space | Aug-2015 | R | UFGS has been revised throughout. Modifications included references and requirements for the following in accordance with the update of DoD Aboveground Storage Tank Standard AW 78-24-27: geotextile fabric, geotextile filter fabric and sand cushions. | |
May-2014 | S | UFGS 23 34 23.00 40 HVAC Power Ventilators | May-2014 | R | Tri-Annual Database Maintenance (TADM) completed | |
Nov-2011 | N | UFGS 01 57 19.00 20 Temporary Environmental Controls | Nov-2011 | R | Added note in subpart 3.4.2.1 | |
Nov-2011 | N | UFGS 03 30 00 Cast-In-Place Concrete | Nov-2011 | R | Modified note in subpart 2.4.10.1; modified subparts 2.3.4.1, 2.4.6, 2.4.10.1, 2.6.2, 3.3.9, 3.8.3, 3.8.6, 3.8.9; removed note and modified subpart 3.7.2 | |
Nov-2011 | N | UFGS 03 45 00 Precast Architectural Concrete | Nov-2011 | R | Modified subpart 2.5.16 | |
Nov-2011 | N | UFGS 05 12 00 Structural Steel | Nov-2011 | R | Modified subparts 3.9.1.1 and 3.9.4.2; removed subpart 2.1.2.3 | |
Nov-2011 | N | UFGS 05 30 00 Steel Decks | Nov-2011 | R | Modified subpart 1.4 | |
Nov-2011 | N | UFGS 07 21 16 Mineral Fiber Blanket Insulation | Nov-2011 | R | Modified subpart 2.2 | |
Nov-2011 | N | UFGS 07 31 13 Asphalt Shingles | Nov-2011 | R | Added subpart 1.6; modified subpart 2.1.1 | |
Nov-2011 | N | UFGS 08 36 19 Vertical Lift Doors | Nov-2011 | R | Modified subparts 2.2, 2.4, 2.4.3, 2.4.4, 2.5 and 3.1.1.1 | |
Nov-2011 | N | UFGS 13 34 19 Metal Building Systems | Nov-2011 | R | Modified subparts 1.2.1.4 and 1.2.1.5 | |
Aug-2011 | N | UFGS 01 11 00 Summary of Work | Aug-2011 | R | Modifed note before PART 1; modified note in subpart 1.14.1; added note in part 1.5; removed all notes in PART 3 | |
Aug-2011 | N | UFGS 01 20 00.00 20 Price and Payment Procedures | Aug-2011 | R | Modified subpart 1.5.1 | |
Aug-2011 | A | UFGS 01 78 00 Closeout Submittals | Aug-2011 | R | Added NAVFAC Sustainable & Energy Data Record Card (tailored) | |
Aug-2011 | N | UFGS 02 82 16.00 20 Engineering Control of Asbestos Containing Materials | Aug-2011 | R | Modified references in subparts 1.2.2, 1.2.24 and 1.3.6 | |
Aug-2011 | N | UFGS 02 82 33.13 20 Removal/Control and Disposal of Paint with Lead | Aug-2011 | R | Modified reference in subpart 1.5.2.6 | |
Aug-2011 | N | UFGS 02 83 13.00 20 Lead in Construction | Aug-2011 | R | Modified reference in subpart 1.5.2.6 | |
Aug-2011 | N | UFGS 03 52 00 Lightweight Concrete Roof Insulation | Aug-2011 | R | Removed subpart 3.6.2 | |
Aug-2011 | N | UFGS 03 52 16.19 Lightweight Insulation Concrete Overlay | Aug-2011 | R | Removed subpart 3.6.2 | |
May-2015 | S | UFGS 01 75 00.00 40 Starting and Adjusting | May-2015 | R | NASA reclassified this as fifth level; renumbered May 2012 version of UFGS 01 75 00 with same title; incorporated Non-Technical CCR 4149 in Subpart 1.2.1. | |
Aug-2011 | N | UFGS 07 11 13 Bituminous Dampproofing | Aug-2011 | R | Modified references in subpart 2.6.1 | |
May-2015 | S | UFGS 03 41 16.08 Precast Concrete Slabs (MAX. SPAN 8 FEET O.C.) | May-2015 | R | Title was changed from PRECAST CONCRETE SLABS (MAX. SPAN 8'- 0" O.C.) because the double quotation marks can throw off the SI Tailoring Options Export feature; performed Tri-Annual Database Maintenance (TADM). | |
May-2015 | S | UFGS 03 62 16 Metallic Non-Shrink Grouting | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
Aug-2011 | N | UFGS 07 22 00 Roof and Deck Insulation | Aug-2011 | R | Modified subparts 1.2, 2.1.1, 2.1.3, 3.1.1; Added subparts 1.4.4 , 1.4.5 and 2.2.2 | |
May-2015 | S | UFGS 05 14 00.13 Welding Structural Aluminum Framing | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2015 | N | UFGS 05 30 00 Steel Decks | May-2015 | R | Major revisions to comply with IBC 2012 | |
May-2015 | N | UFGS 05 40 00 Cold-Formed Metal Framing | May-2015 | R | Major revisions to comply with IBC 2012 | |
May-2015 | S | UFGS 08 22 20 Fiberglass Reinforced Plastic (FRP) Doors and Frames | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2015 | S | UFGS 09 23 82 Fireproof Gypsum Plastering | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2015 | S | UFGS 10 44 16 Fire Extinguishers | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2015 | S | UFGS 23 37 13.00 40 Diffusers, Registers, and Grills | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2015 | N | UFGS 23 52 43.00 20 Low Pressure Water Heating Boilers (Under 800,000 BTU/HR Output) | May-2015 | R | Revised throughout to incorporate CCRs 1006, 4267, and 2584. Modifications included references, boiler installation requirements, detail drawings, water analysis, safety standards, submittals, efficiency requirements, general requirements, controls, safety features, operational tests, and acceptance operational test and inspection. | |
May-2015 | N | UFGS 23 52 46.00 20 Low Pressure Water Heating Boilers (Over 800,000 BTU/HR Output) | May-2015 | R | Revised throughout to incorporate CCRs 1007 and 4266. Modifications included references, boiler installation requirements, detail drawings, water analysis, safety standards, submittals, controls, safety features, operational tests, and acceptance operational test and inspection. | |
May-2015 | N | UFGS 26 23 00 Low Voltage Switchgear | May-2015 | R | This is a "REVISED" guide specification section number that, in part, replaces the original UFGS 26 23 00 Switchboards and Switchgear. The original guide specification was separated into two specifications: UFGS 26 23 00 Low Voltage Switchgear, and UFGS 26 24 13 Switchboards. This section has had a complete technical update. | |
Aug-2011 | N | UFGS 08 14 00 Wood Doors | Aug-2011 | R | Modified references and other minor revisions in subparts 1.2, 1.3, 1.6, 2.1, 2.1.2.2, 2.1.7, 2.3.6.4, 2.3.7 and 3.1.1; added 1.4 | |
May-2015 | S | UFGS 26 60 13.00 40 Low-Voltage Motors | May-2015 | R | Tri-Annual Database Maintenance (TADM) completed | |
May-2015 | N | UFGS 48 14 13.00 20 Solar Liquid Flat Plate and Evacuated Tube Collectors | May-2015 | R | Title changed from SOLAR LIQUID FLAT PLATE COLLECTORS. Section revised throughout. Incorporated evacuated tube collectors. Modifications included in Technical Notes, references and submittals. | |
Aug-2011 | N | UFGS 08 36 13 Sectional Overhead Doors | Aug-2011 | R | Modified subparts 2.1.7, 2.2, 2.3, 2.4.1, 2.4.1.1, 2.4.5, 2.6.1, 2.6.4, 2.7, 2.8 | |
Aug-2011 | N | UFGS 08 44 00 Curtain Wall and Glazed Assemblies | Aug-2011 | R | Modified references in subparts 2.1.3, 2.4.5 and 2.8.4 | |
Aug-2011 | N | UFGS 08 51 23 Steel Windows | Aug-2011 | R | Modified references in subpart 2.7.2 | |
Aug-2011 | N | UFGS 08 52 00 Wood Windows | Aug-2011 | R | Modified reference in subpart 2.2 | |
Aug-2011 | N | UFGS 08 53 00 Plastic Windows | Aug-2011 | R | Modified subpart 2.4.9.2; modified reference in subparts 1.2, 1.3.1, 1.3.2, 2.1, 2.2.1, 2.3.1, 2.4, 2.4.5 | |
Aug-2011 | N | UFGS 08 56 46.10 20 Radio Frequency Shielded Enclosures, Demountable Type | Aug-2011 | R | Modified subpart 2.11 | |
Aug-2011 | N | UFGS 08 56 46.20 20 Radio Frequency Shielded Enclosures, Welded Type | Aug-2011 | R | Modified references in subparts 2.2.1 and 2.10 | |
Aug-2011 | N | UFGS 08 56 53 Blast Resistant Tempered Glass Windows | Aug-2011 | R | Modified subpart 2.5.10 | |
Aug-2011 | N | UFGS 08 81 00 Glazing | Aug-2011 | R | Modified references in subparts 2.1.4, 2.2, 2.2.1, 2.2.2.1, 2.3.2 and 2.4.1. | |
Aug-2011 | N | UFGS 12 36 00.00 20 Manufactured Vanities | Aug-2011 | R | Modified references in subparts 2.1 and 3.1.2; removed 2.5 | |
Aug-2011 | N | UFGS 22 00 00 Plumbing, General Purpose | Aug-2011 | R | Modified references in subparts 2.3, 2.4.24, 3.1, 3.1.3.6, 3.9.3.2 and 3.13 Table II #13 | |
Aug-2011 | S | UFGS 22 14 29.00 Sump Pumps | Aug-2011 | R | Compliance with CSI SectionFormat; Submittal Article Compliance | |
Aug-2011 | S | UFGS 23 82 43.00 40 Electric Duct Heaters | Aug-2011 | R | Compliance with CSI SectionFormat; Submittal Article Compliance | |
Aug-2011 | S | UFGS 23 82 46.00 40 Electric Unit Heaters | Aug-2011 | R | Compliance with CSI SectionFormat; Submittal Article Compliance | |
Aug-2011 | N | UFGS 26 12 19.10 Three-Phase, Liquid-Filled Pad-Mounted Transformers | Aug-2011 | R | Major revision | |
Aug-2011 | N | UFGS 26 13 00.00 20 SF6/High-Firepoint Fluids Insulated Pad-Mounted Switchgear | Aug-2011 | R | Major revision and title change (was SF6 Insulated Pad-Mounted Switchgear) | |
Aug-2011 | S | UFGS 26 28 21.00 40 Automatic Transfer Switches | Aug-2011 | R | Compliance with CSI SectionFormat; Submittal Article Compliance |