Unified Facilities Guide Specifications (UFGS)  Subscribe to Unified Facilities Guide Specifications (UFGS)

UFGS Master Updated February 13, 2024; Posted February 22, 2024

Unified Facilities Guide Specifications (UFGS) are a joint effort of the U.S. Army Corps of Engineers (USACE), the Naval Facilities Engineering Systems Command (NAVFAC), and the Air Force Civil Engineer Center (HQ AFCEC). UFGS are for use in specifying construction for the military services.

On September 30, 2023, NASA officially withdrew from the UFGS program. All NASA-specific UFGS sections (40) have been removed from the UFGS Master, though some UFGS sections may still include a NASA section reference. The final NASA UFGS Master is available on the WBDG at NASA UFGS Master Specifications.

The Unified Facilities Guide Specifications (UFGS) are published only in electronic format and are intended to be used with SpecsIntact software. The UFGS Master complies with UFC 1-300-02. SpecsIntact supports the UFGS format. SpecsIntact can still open Masters or Jobs created with older versions of the UFGS format.

Updated UFGS are posted quarterly in February, May, August, and November.

UFGS that have been unified for use by all participating agencies have a level 3 or level 4 Section number. The UFGS uses level 5 to identify a single-agency specification. The number "10" is used by USACE, "20" by NAVFAC, and "30" by AFCEC. The order of precedence for selecting UFGS sections for a project is generally:

  1. Regional UFGS if required by the contract or published on WBDG
  2. Single-agency UFGS for whom project is being developed
  3. Unified UFGS
  4. UFGS identified as specific to another DoD Service (for DoD projects only)

Points of contact and procedures for the development and maintenance of UFGS documents are prescribed in the latest edition of MIL-STD-3007.

The UFGS Section Template is now provided in the UFGS Master with each quarterly release and can be found under Tools in the SpecsIntact Explorer.

SpecsIntact for NMCI Users

Questions, comments, suggestions and recommended changes for guide specifications should be submitted as a Criteria Change Request (CCR). To submit, click on the CCR link next to the document title (below). CCRs are not appropriate when they pertain to a specific project solicitation, request for proposal, or after a project award. Questions or interpretations pertaining to these documents or situations should be referred to the Contracting Officer.

Click the 'Title' or 'Date' heading to sort by ascending or descending order. Narrow the list by selecting a 'Division' option from the drop-down or view archived documents by selecting from the 'Status' drop-down and clicking 'Apply'.

Active documents are available in the following formats:   SpecsIntact (SEC) in compressed ZIP  |   Adobe Acrobat (PDF)

Archived release files are available in  Adobe Acrobat (PDF) in compressed ZIP

  Indicates the UFGS has an attachment. Click the title to view the attachment under 'Related Materials'.

Titlesort descending Date View CCR
UFGS 05 05 20 Post-Installed Concrete and Masonry Anchors   05-01-2022  PDF |  ZIP  CCR
UFGS 05 05 23.13 10 Ultrasonic Inspection of Weldments   08-01-2018  PDF |  ZIP  CCR
UFGS 05 05 23.16 Structural Welding   08-01-2018  PDF |  ZIP  CCR
UFGS 05 12 00 Structural Steel   08-01-2018  PDF |  ZIP  CCR
UFGS 05 14 00.13 Welding Structural Aluminum Framing   11-01-2019  PDF |  ZIP  CCR
UFGS 05 21 00 Steel Joist Framing   05-01-2015  PDF |  ZIP  CCR
UFGS 05 30 00 Steel Decks   05-01-2015  PDF |  ZIP  CCR
UFGS 05 40 00 Cold-Formed Metal Framing   05-01-2015  PDF |  ZIP  CCR
UFGS 05 50 13 Miscellaneous Metal Fabrications   05-01-2017  PDF |  ZIP  CCR
UFGS 05 50 14 Structural Metal Fabrications   08-01-2018  PDF |  ZIP  CCR
UFGS 05 50 15 Civil Works Fabrications   08-01-2018  PDF |  ZIP  CCR
UFGS 05 51 00 Metal Stairs   08-01-2023  PDF |  ZIP  CCR
UFGS 05 51 33 Metal Ladders   02-01-2016  PDF |  ZIP  CCR
UFGS 05 52 00 Metal Railings   08-01-2023  PDF |  ZIP  CCR
UFGS 05 59 10 Rolling Cover for Aviation Refueling Vaults   11-01-2022  PDF |  ZIP  CCR
UFGS 05 59 20 Fabrication Of Hydraulic Steel Structures   05-01-2021  PDF |  ZIP  CCR
UFGS 05 72 00 Decorative Metal Specialties   08-01-2023  PDF |  ZIP  CCR
UFGS 06 10 00 Rough Carpentry   08-01-2016  PDF |  ZIP  CCR
UFGS 06 13 33 Pier Timberwork   11-01-2016  PDF |  ZIP  CCR
UFGS 06 17 19 Cross-Laminated Timber   11-01-2016  PDF |  ZIP  CCR
UFGS 06 18 00 Glued-Laminated Construction   08-01-2023  PDF |  ZIP  CCR
UFGS 06 20 00 Finish Carpentry   08-01-2016  PDF |  ZIP  CCR
UFGS 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets   08-01-2010  PDF |  ZIP  CCR
UFGS 06 61 16 Solid Surfacing Fabrications   08-01-2020  PDF |  ZIP  CCR
UFGS 06 71 33 Fiberglass Reinforced Plastic (FRP) Ladders   08-01-2023  PDF |  ZIP  CCR
UFGS 06 73 01 Fiberglass Reinforced Plastic (FRP) Grating   08-01-2023  PDF |  ZIP  CCR
UFGS 06 82 14 Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings   08-01-2023  PDF |  ZIP  CCR
UFGS 07 11 13 Bituminous Dampproofing   08-01-2023  PDF |  ZIP  CCR
UFGS 07 12 00 Built-Up Bituminous Waterproofing   02-01-2016  PDF |  ZIP  CCR
UFGS 07 13 53 Elastomeric Sheet Waterproofing   02-01-2016  PDF |  ZIP  CCR
UFGS 07 14 00 Fluid-Applied Waterproofing   08-01-2023  PDF |  ZIP  CCR
UFGS 07 16 19 Metallic Oxide Waterproofing   08-01-2023  PDF |  ZIP  CCR
UFGS 07 17 00 Bentonite Waterproofing   02-01-2016  PDF |  ZIP  CCR
UFGS 07 19 00 Water Repellents   08-01-2023  PDF |  ZIP  CCR
UFGS 07 21 13 Board and Block Insulation   08-01-2023  PDF |  ZIP  CCR
UFGS 07 21 16 Mineral Fiber Blanket Insulation   08-01-2023  PDF |  ZIP  CCR
UFGS 07 21 23 Loose Fill Thermal Insulation   08-01-2023  PDF |  ZIP  CCR
UFGS 07 22 00 Roof and Deck Insulation   08-01-2023  PDF |  ZIP  CCR
UFGS 07 24 00 Exterior Insulation and Finish Systems   08-01-2023  PDF |  ZIP  CCR
UFGS 07 27 10 Building Air Barrier System   08-01-2023  PDF |  ZIP  CCR
UFGS 07 27 19.01 Self-Adhering Air Barriers   08-01-2023  PDF |  ZIP  CCR
UFGS 07 27 26 Fluid-Applied Membrane Barriers   08-01-2023  PDF |  ZIP  CCR
UFGS 07 27 36 Spray Foam Air Barriers   08-01-2023  PDF |  ZIP  CCR
UFGS 07 31 13 Asphalt Shingles   08-01-2016  PDF |  ZIP  CCR
UFGS 07 31 26 Slate Shingles   08-01-2009  PDF |  ZIP  CCR
UFGS 07 32 13 Roof Tiles   04-01-2006  PDF |  ZIP  CCR
UFGS 07 32 14 Clay Tile Roofing Replacement or Repair   04-01-2006  PDF |  ZIP  CCR
UFGS 07 41 13 Metal Roof Panels   05-01-2011  PDF |  ZIP  CCR
UFGS 07 41 13.16 Copper Roof Panels   08-01-2009  PDF |  ZIP  CCR
UFGS 07 41 63 Fabricated Roof Panel Assemblies   11-01-2016  PDF |  ZIP  CCR
UFGS 07 42 13 Metal Wall Panels   05-01-2011  PDF |  ZIP  CCR
UFGS 07 42 63 Fabricated Wall Panel Assemblies   05-01-2011  PDF |  ZIP  CCR
UFGS 07 51 13 Built-Up Asphalt Roofing   05-01-2012  PDF |  ZIP  CCR
UFGS 07 52 00 Modified Bituminous Membrane Roofing   05-01-2012  PDF |  ZIP  CCR
UFGS 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing   05-01-2012  PDF |  ZIP  CCR
UFGS 07 54 19 Polyvinyl Chloride Roofing   08-01-2023  PDF |  ZIP  CCR
UFGS 07 55 00 Protected Membrane Roofing (PMR)   08-01-2009  PDF |  ZIP  CCR
UFGS 07 57 13 Sprayed Polyurethane Foam (SPF) Roofing   05-01-2011  PDF |  ZIP  CCR
UFGS 07 60 00 Flashing and Sheet Metal   08-01-2023  PDF |  ZIP  CCR
UFGS 07 61 14.00 20 Steel Standing Seam Roofing   08-01-2016  PDF |  ZIP  CCR
UFGS 07 61 15.00 20 Aluminum Standing Seam Roofing   08-01-2016  PDF |  ZIP  CCR
UFGS 07 62 13 Copper Sheet Metal Flashing and Trim   08-01-2009  PDF |  ZIP  CCR
UFGS 07 72 20 Gravity-Type Roof Ventilators   08-01-2023  PDF |  ZIP  CCR
UFGS 07 81 00 Spray-Applied Fireproofing   02-01-2011  PDF |  ZIP  CCR
UFGS 07 84 00 Firestopping   05-01-2010  PDF |  ZIP  CCR
UFGS 07 92 00 Joint Sealants   08-01-2023  PDF |  ZIP  CCR
UFGS 08 01 52 Operation and Maintenance of Wood Windows   08-01-2009  PDF |  ZIP  CCR
UFGS 08 11 13 Steel Doors and Frames   08-01-2020  PDF |  ZIP  CCR
UFGS 08 11 16 Aluminum Doors and Frames   05-01-2017  PDF |  ZIP  CCR
UFGS 08 11 73 Sliding Fire Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 08 13 73 Sliding Metal Doors   02-01-2011  PDF |  ZIP  CCR
UFGS 08 14 00 Wood Doors   08-01-2016  PDF |  ZIP  CCR
UFGS 08 22 20 Fiberglass Reinforced Plastic (FRP) Doors and Frames   11-01-2019  PDF |  ZIP  CCR
UFGS 08 31 00 Access Doors and Panels   05-01-2017  PDF |  ZIP  CCR
UFGS 08 32 13 Aluminum Sliding Glass Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 08 33 13 Coiling Counter Doors   05-01-2009  PDF |  ZIP  CCR
UFGS 08 33 23 Overhead Coiling Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 08 34 01 Forced Entry Resistant Components   08-01-2009  PDF |  ZIP  CCR
UFGS 08 34 02 Bullet-Resistant Components   08-01-2009  PDF |  ZIP  CCR
UFGS 08 34 16 Corrosion Control Hangar Doors   05-01-2017  PDF |  ZIP  CCR
UFGS 08 34 16.10 Horizontal Rolling Steel Doors   11-01-2021  PDF |  ZIP  CCR
UFGS 08 34 16.20 Vertical Lift Fabric Doors   08-01-2021  PDF |  ZIP  CCR
UFGS 08 34 49.00 20 Hemp Shielded Door   11-01-2022  PDF |  ZIP  CCR
UFGS 08 34 58 File Room Doors and Frames   08-01-2008  PDF |  ZIP  CCR
UFGS 08 34 59 Vault Doors and Day Gates   08-01-2008  PDF |  ZIP  CCR
UFGS 08 34 63 Detention Hollow Metal Frames, Doors, and Door Frames   05-01-2011  PDF |  ZIP  CCR
UFGS 08 34 73 Sound Control Door Assemblies   11-01-2019  PDF |  ZIP  CCR
UFGS 08 36 13 Sectional Overhead Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 08 36 19 Vertical Lift Doors   08-01-2020  PDF |  ZIP  CCR
UFGS 08 39 53 Blast Resistant Doors (Earth Covered Magazines)   02-01-2019  PDF |  ZIP  CCR
UFGS 08 39 54 Blast Resistant Doors   08-01-2009  PDF |  ZIP  CCR
UFGS 08 41 13 Aluminum-Framed Entrances and Storefronts   11-01-2016  PDF |  ZIP  CCR
UFGS 08 44 00 Curtain Wall and Glazed Assemblies   05-01-2019  PDF |  ZIP  CCR
UFGS 08 51 13 Aluminum Windows   05-01-2019  PDF |  ZIP  CCR
UFGS 08 51 23 Steel Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 08 51 69.10 Aluminum Storm Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 08 52 00 Wood Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 08 53 00 Plastic Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 08 56 46.10 20 Radio Frequency Shielded Enclosures, Demountable Type   08-01-2011  PDF |  ZIP  CCR
UFGS 08 56 46.20 20 Radio Frequency Shielded Enclosures, Welded Type   08-01-2011  PDF |  ZIP  CCR
UFGS 08 56 53 Blast Resistant Tempered Glass Windows   08-01-2020  PDF |  ZIP  CCR
UFGS 08 56 63 Detention and Security Windows   04-01-2006  PDF |  ZIP  CCR
UFGS 08 60 45 [Skylights] [ and ] [Translucent Panels]   08-01-2020  PDF |  ZIP  CCR
UFGS 08 71 00 Door Hardware   02-01-2016  PDF |  ZIP  CCR
UFGS 08 71 63 Detention Hardware   04-01-2006  PDF |  ZIP  CCR
UFGS 08 71 63.10 Electrical Locking Control for Brigs   11-01-2022  PDF |  ZIP  CCR
UFGS 08 81 00 Glazing   05-01-2019  PDF |  ZIP  CCR
UFGS 08 87 23.13 Safety Films   08-01-2009  PDF |  ZIP  CCR
UFGS 08 88 53 Detention and Security Glazing   05-01-2011  PDF |  ZIP  CCR
UFGS 08 88 58 Air Traffic Control Tower Cab Glass   05-01-2014  PDF |  ZIP  CCR
UFGS 08 91 00 Metal [Wall] [and] [Door] Louvers   08-01-2020  PDF |  ZIP  CCR
UFGS 09 01 90.50 Preparation of Historic Wood and Metal Surfaces for Painting   05-01-2009  PDF |  ZIP  CCR
UFGS 09 06 00 Schedules for Finishes   08-01-2022  PDF |  ZIP  CCR
UFGS 09 22 00 Supports for Plaster and Gypsum Board   02-01-2010  PDF |  ZIP  CCR
UFGS 09 22 36 Lath   01-01-2008  PDF |  ZIP  CCR
UFGS 09 23 00 Gypsum Plastering   08-01-2016  PDF |  ZIP  CCR
UFGS 09 23 82 Fireproof Gypsum Plastering   11-01-2019  PDF |  ZIP  CCR
UFGS 09 24 23 Cement Stucco   08-01-2017  PDF |  ZIP  CCR
UFGS 09 26 00 Veneer Plaster   08-01-2016  PDF |  ZIP  CCR
UFGS 09 29 00 Gypsum Board   08-01-2016  PDF |  ZIP  CCR
UFGS 09 30 10 Ceramic, Quarry, and Glass Tiling   08-01-2020  PDF |  ZIP  CCR
UFGS 09 35 16 Chemical-Resistant Quarry Tiling   08-01-2016  PDF |  ZIP  CCR
UFGS 09 51 00 Acoustical Ceilings   08-01-2020  PDF |  ZIP  CCR
UFGS 09 62 38 Static-Control Flooring   08-01-2017  PDF |  ZIP  CCR
UFGS 09 64 00 Portable (Demountable) Wood Flooring   08-01-2016  PDF |  ZIP  CCR

Pages