DOD CAD Resources  Subscribe to DOD CAD Resources

Military Health System (MHS) Templates

The Military Health System (MHS) Templates illustrate specific room by room equipment layouts, which define and provide for specialized working environments within medical facilities according to various departmental functions.

Suggest a Change/Improvement

Click the 'Title' or 'Date' heading to sort by ascending or descending order. View archived documents by selecting from the 'Status' drop-down and clicking 'Apply'.

These documents are available in the following format:
 Adobe Acrobat (PDF)  |   Design Web Format™ (DWF)  |   Revit (RVT)

Title Datesort descending View
EYVF1 - Eye, Visual Field 04-01-2013  PDF |  DWF |  RVT
EXUD1/TLTU1 - Exam, Urodynamics with Toilet 01-15-2015  PDF |  DWF |  RVT
ORNS1 - Operating Room, Neurology 01-15-2015  PDF |  DWF |  RVT
EYEL2 - Eye Lane, Electronic 01-15-2015  PDF |  DWF |  RVT
EYFC1 - Eye, Fundus Camera Room 01-15-2015  PDF |  DWF |  RVT
VS001 - Operating Room, Veterinary 01-15-2015  PDF |  DWF |  RVT
EYVS1 - Eye, Vision Screening 01-15-2015  PDF |  DWF |  RVT
RRSS1 - Recovery Station, Phase I 01-15-2015  PDF |  DWF |  RVT
EXRG6/TLTU1 - Exam, Isolation, Negative Pressure with Toilet, Unisex 01-30-2015  PDF |  DWF |  RVT
NBCD3 - Decontamination Anteroom 01-30-2015  PDF |  DWF |  RVT
TRGM1 - Treatment Room, General, 1 Bed 01-30-2015  PDF |  DWF |  RVT
NBCD4 - Decontamination Patient Prep 01-30-2015  PDF |  DWF |  RVT
ORGS1 - Operating Room, Integrated 01-30-2015  PDF |  DWF |  RVT
NBCD5 - Decontamination Patient Transition 01-30-2015  PDF |  DWF |  RVT
VEX01 - Exam / Treatment, Veterinary 01-30-2015  PDF |  DWF |  RVT
DNTG1 - Dental Treatment Room, General 01-30-2015  PDF |  DWF |  RVT
NCWD1 - Nourishment Center 01-30-2015  PDF |  DWF |  RVT
ORSR1 - Sterile Processing, Surgical Services 01-30-2015  PDF |  DWF |  RVT
VEX02 - Procedure, Veterinary 01-30-2015  PDF |  DWF |  RVT
DNTG3 - Dental Treatment Room, Two Chair 01-30-2015  PDF |  DWF |  RVT
NMGS1 - Scanning Room, Nuclear Medicine 01-30-2015  PDF |  DWF |  RVT
PEHS1 - Hearing/Screening Booth, 1 Person 01-30-2015  PDF |  DWF |  RVT
General Guidance: General Information on Medical Templates 01-30-2015  PDF |  RVT
EYOT2 - Exam, Ophthalmology 01-30-2015  PDF |  DWF |  RVT
NMUR1 - Nuclear Medicine, Uptake Room 01-30-2015  PDF |  DWF |  RVT
PTEM1 - Electromyography (EMG) 01-30-2015  PDF |  DWF |  RVT
DNTP1 - Dental Treatment Room, Prosthodontics 01-30-2015  PDF |  DWF |  RVT
NYIR1/NYAR1 - Bedroom, Nursery, Airborne Infection Isolation and Anteroom, Nursery Airborne Infection Isolation 01-30-2015  PDF |  DWF |  RVT
PTTC1 - Treatment Cubicle, Physical Therapy 01-30-2015  PDF |  DWF |  RVT
BRMS1/TLTS2 - Bedroom, Medical/Surgical with Toilet/Shower 01-30-2015  PDF |  DWF |  RVT
DNTS1 - Dental Treatment Room, Oral Surgery 01-30-2015  PDF |  DWF |  RVT
NYNN1 - Nursery, Level I 01-30-2015  PDF |  DWF |  RVT
VXER1 - Xray, Veterinary 01-30-2015  PDF |  DWF |  RVT
DNXC1 - Dental X-Ray, Cone Beam 01-30-2015  PDF |  DWF |  RVT
LBVP1 - Laboratory, Venipuncture 01-30-2015  PDF |  DWF |  RVT
NYUN2 - Bedroom, NICU, Multiple Birth 01-30-2015  PDF |  DWF |  RVT
RROP2 - Recovery Cubicle, Phase II 01-30-2015  PDF |  DWF |  RVT
UCCL2 - Utility, Scope Wash, Clean 01-30-2015  PDF |  DWF |  RVT
BRUN1/TLTS2 - Bedroom, Acuity Adaptable with Toilet/Shower 01-30-2015  PDF |  DWF |  RVT
DNXI1 - Dental X-Ray, Intraoral 01-30-2015  PDF |  DWF |  RVT
LBVP2 - Laboratory, Venipuncture, Multi-Station 01-30-2015  PDF |  DWF |  RVT
OFD01 - Office, Provider, Private 01-30-2015  PDF |  DWF |  RVT
USCL2 - Utility, Scope Wash, Soiled 01-30-2015  PDF |  DWF |  RVT
CRA02 - Conference Room, Medium 01-30-2015  PDF |  DWF |  RVT
LDAT1/TLTU1 - Antepartum Testing with Toilet 01-30-2015  PDF |  DWF |  RVT
OFD02 - Office, Provider, Shared 01-30-2015  PDF |  DWF |  RVT
TLTS1 - Toilet, Shower, Single 01-30-2015  PDF |  DWF |  RVT
CSDE1 - Workroom, Sterile Processing, Decontamination 01-30-2015  PDF |  DWF |  RVT
DUTY1/TLTS1 - On-Call Room with Toilet, Shower, Single 01-30-2015  PDF |  DWF |  RVT
LDAT2/TLTU1 - Antepartum Testing, Multiple Station with Toilet 01-30-2015  PDF |  DWF |  RVT
OPCR2 - Cast Room, Multi-Station 01-30-2015  PDF |  DWF |  RVT
TLTS2 - Toilet/Shower 01-30-2015  PDF |  DWF |  RVT
XDM01 - Xray, Mammography 01-30-2015  PDF |  DWF |  RVT
EXEN1 - Exam Room, ENT 01-30-2015  PDF |  DWF |  RVT
LDDR1 - Operating Room, Labor & Delivery, C-Section 01-30-2015  PDF |  DWF |  RVT
TLTU1 - Toilet 01-30-2015  PDF |  DWF |  RVT
XDUS1/TLTU1 - Xray, Ultrasound with Toilet 01-30-2015  PDF |  DWF |  RVT
DNPC2 - Dental, Porcelain/Ceramic Room, Medium 01-30-2015  PDF |  DWF |  RVT
EXER1 - Exam, Emergency Room 01-30-2015  PDF |  DWF |  RVT
LDEP1/TLTU1 - Labor & Delivery, Exam & Preparation with Toilet 01-30-2015  PDF |  DWF |  RVT
TREE1 - Procedure Room, Endoscopy 01-30-2015  PDF |  DWF |  RVT
DNPL2 - Dental Prosthodontics Lab, Medium 01-30-2015  PDF |  DWF |  RVT
EXRG1 - Exam Room 01-30-2015  PDF |  DWF |  RVT
LDRP1/SRSE1/TLTS2 - Labor & Delivery Room with Storage Room, Equipment/Shelving and Toilet/Shower 01-30-2015  PDF |  DWF |  RVT
OPRT1 - Outpatient Respiratory Treatment 01-30-2015  PDF |  DWF |  RVT
TRET3 -Trauma/Resuscitation, Level I/II 01-30-2015  PDF |  DWF |  RVT
EXRG4 - Exam, Screening 01-30-2015  PDF |  DWF |  RVT
NBCD2 - Decontamination Shower 01-30-2015  PDF |  DWF |  RVT
OPTM1 - Stress Testing, Treadmill 01-30-2015  PDF |  DWF |  RVT
DNSC4 - Dental, Instrument Decontamination, Medium 02-01-2016  PDF |  DWF |  RVT
ORCS1 - Operating Room, Cystoscopy 02-01-2016  PDF |  DWF |  RVT
DNSC5 - Dental Instrument, Sterilization, Medium 02-01-2016  PDF |  DWF |  RVT
TRPE1/TLTU1 - Treatment Room, Proctoscopy (LGI) with Toilet 02-01-2016  PDF |  DWF |  RVT
DNSC6 - Dental Instrument Storage, Sterile, Medium 02-01-2016  PDF |  DWF |  RVT
EYEL1/WRC03 - Eyelane with Sub-Waiting Room 02-01-2016  PDF |  DWF |  RVT
VNEC1 - Necropsy, Veterinary 02-01-2016  PDF |  DWF |  RVT
DNTG4 - Dental Treatment Room, Multi-Chair 02-01-2016  PDF |  DWF |  RVT
BRII2/BRAR2/TLTS2 - Bedroom, ICU/CCU, Protective Environment with Anteroom, ICU/CCU, Protective Environment and Toilet/Shower 02-01-2016  PDF |  DWF |  RVT
VSPD1 - Prep, Veterinary, Surgery/Dental 02-01-2016  PDF |  DWF |  RVT
RDC01 - Renal Dialysis Room, Airborne Infection Isolation 02-01-2016  PDF |  DWF |  RVT
BRNP2/TLTP3 - Bedroom, Behavioral Health (Double Occupancy) with Toilet/Shower, Behavioral Health 02-01-2016  PDF |  DWF |  RVT
BRNP5/BRNP6/TLTP2 - Seclusion Room - Anteroom, Seclusion - Toilet, Seclusion 02-01-2016  PDF |  DWF |  RVT
DNXS1 - Dental, X-Ray Extraoral / Panoramic / Cephalometric Suite 02-01-2016  PDF |  DWF |  RVT
XDCY1 - Xray, Cystology 02-01-2016  PDF |  DWF |  RVT
CSIA2 - Clean Workroom, Instrument Set Assembly, Medium 02-01-2016  PDF |  DWF |  RVT
OPIR1 - Immunizations 02-01-2016  PDF |  DWF |  RVT
XVC01 - X-Ray Viewing / Consultation Area 02-01-2016  PDF |  DWF |  RVT
OPPF1 - Pulmonary Function Screening 02-01-2016  PDF |  DWF |  RVT
DNPL3 - Dental Laboratory, Prosthodontic, Full Service 02-01-2016  PDF |  DWF |  RVT
TREY3 - Treatment, Eye-Lasik / PRK 02-01-2016  PDF |  DWF |  RVT